FAQ
FAQAbout Products
FAQ
Keyword Search
Drive Products
-
FREQROL-A800(144)
FREQROL-F800(89)
FREQROL-A700(352)
FREQROL-D700(261)
FREQROL-E700(394)
FREQROL-F700(296)
FREQROL-F700P(295)
FREQROL-F700PJ(252)
FREQROL-A024(40)
FREQROL-A100(21)
FREQROL-A200(32)
FREQROL-A500(123)
FREQROL-B(10)
FREQROL-E500(85)
FREQROL-F400(2)
FREQROL-F500(15)
FREQROL-S500(11)
FREQROL-U100(16)
FREQROL-V200(52)
FREQROL-Z020(1)
FREQROL-Z024(2)
FREQROL-Z100(2)
FREQROL-Z123(2)
FREQROL-Z200(3)
FREQROL-Z300(2)
SC-A(12)
Engineering Software(43)
Magnet motor drive(9)
Peripheral devices(7)
Options(129)
Plug-in Options(30)
Others(53)
FAQ within [ Drive Products ]
-
1. Select the circuit breaker and MC in accordance with the inverter type.2. Select the power factor improving reactor in accordance with the motor output. More Details >>
- No:21946
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
Installation of external thermal
Since the inverter has a built-in motor overheat protective function called "electronic thermal O/L relay", the external thermal is not required. (If you use... More Details >>
- No:21545
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL
-
Simple torque control using stall prevention function
Basically, torque control cannot be performed. Instead, control speed to adjust the winding torque. It is possible to use the current limit function to preve... More Details >>
- No:21493
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-A500
-
When measuring current, if you open the output side while current is flowing on the input side, high voltage is induced and dielectric breakdown may occur wi... More Details >>
- No:21399
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL
-
The function block and ladder language are available. The ST language is not available. More Details >>
- No:21043
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL
-
The torque limit setting is defined as an absolute value. Thus, when -100% is written to the torque limit, the torque is limited at 100%. More Details >>
- No:20920
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL
-
PID control of CC-Link communication
When performing the PID control by CC-Link communication, the X14 signal is disabled. More Details >>
- No:21233
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
Yes, the options are the same as the FR-A800 standard model. Note that two options can be added at maximum. (One option is already used as standard.) Other c... More Details >>
- No:20922
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL
1361-1368 of Total 1368