FAQ within [ Drive Products ]
- 
      
      
The function is only for overheat protection. It does not affect the torque accuracy. More Details >>
- No:21040
 - Release Date:2018/08/22 16:25
 - Category: Inverters-FREQROL
 
 - 
      
Amount of heat generated by the FR-V500L
It is the same as the one by the inverter whose capacity is one-rank higher than the FR-A500L series. More Details >>
- No:20854
 - Release Date:2018/08/22 16:24
 - Category: Inverters-FREQROL
 
 - 
      
      
The 0.75 kW inverter with the single-phase 100 V power supply can be manufactured and is actually commercialized as the FR-U100 series. Manufacturing of the ... More Details >>
- No:21509
 - Release Date:2018/08/22 16:28
 - Category: Inverters-FREQROL
 
 - 
      
      
1. As the measurement condition is unknown, the possible cases are as follows: - If you measured the current on the input side of the inverter, since the cu... More Details >>
- No:21457
 - Release Date:2018/08/22 16:27
 - Category: Inverters-FREQROL
 
 - 
      
      
There is no setting to disable it, but setting a high torque limit level such as 400 % can disable the limit. More Details >>
- No:21217
 - Release Date:2018/08/22 16:26
 - Category: Inverters-FREQROL
 
 - 
      
FR Configurator (English version)
The English version cannot be updated from the Website. FR-SW3-SETUP-WE needs to be purchased. More Details >>
- No:21195
 - Release Date:2018/08/22 16:26
 - Category: Inverters-FREQROL
 
 - 
      
      
Yes. More Details >>
- No:21041
 - Release Date:2018/08/22 16:25
 - Category: Inverters-FREQROL
 
 - 
      
      
The current value can be displayed on the operation panel without regard to the setting of monitor-related parameters. As the current value remains 0 A, the ... More Details >>
- No:21405
 - Release Date:2018/08/22 16:27
 - Category: Inverters-FREQROL
 
 
1361-1368 of Total 1368