FAQ
FAQAbout Products
FAQ
Keyword Search
Drive Products
-
FREQROL-A800(144)
FREQROL-F800(89)
FREQROL-A700(352)
FREQROL-D700(261)
FREQROL-E700(394)
FREQROL-F700(296)
FREQROL-F700P(295)
FREQROL-F700PJ(252)
FREQROL-A024(40)
FREQROL-A100(21)
FREQROL-A200(32)
FREQROL-A500(123)
FREQROL-B(10)
FREQROL-E500(85)
FREQROL-F400(2)
FREQROL-F500(15)
FREQROL-S500(11)
FREQROL-U100(16)
FREQROL-V200(52)
FREQROL-Z020(1)
FREQROL-Z024(2)
FREQROL-Z100(2)
FREQROL-Z123(2)
FREQROL-Z200(3)
FREQROL-Z300(2)
SC-A(12)
Engineering Software(43)
Magnet motor drive(9)
Peripheral devices(7)
Options(129)
Plug-in Options(30)
Others(53)
FAQ within [ Drive Products ]
-
If "1" is not shown on the frequency monitor, some of the parameters necessary for auto tuning may not be set correctly.Set rated motor current of Pr.81 (Num... More Details >>
- No:21751
- Release Date:2018/08/22 16:29
- Category: Inverters-FREQROL , FREQROL-E700 , FREQROL-A700
-
Switching between external operation and NET operation
You can switch between external operation and NET operation by turning ON/OFF the terminal X66 (RM). You can switch while Pr.79 (Operation mode) is set to "6... More Details >>
- No:21688
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , FREQROL-E700 , FREQROL-D700 , FREQROL-A700 , FREQROL-F700 , FREQROL-F700P , FREQROL-F700PJ
-
Switching between external operation and NET operation
You can write frequency setting by setting Pr.339 (Communication speed command source) to "0". More Details >>
- No:21687
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , FREQROL-E700 , FREQROL-D700 , FREQROL-A700 , FREQROL-F700 , FREQROL-F700P , FREQROL-F700PJ
-
Set Pr.338 to "0" (NET) and Pr.339 to "1" or "2". More Details >>
- No:21674
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , FREQROL-E700 , FREQROL-D700 , FREQROL-A700 , FREQROL-F700 , FREQROL-F700P , FREQROL-F700PJ
-
By adopting Mitsubishi proprietary digital vector control, high torque (150% 60 sec) and fast-response (speed loop 200 rad/sec) are achieved. The speed contr... More Details >>
- No:21664
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , FREQROL-V200
-
1. Such a behavior does not usually happen. (1) The operation command (STF) is not input, contact faults are present, or wire is broken. (2) The output shu... More Details >>
- No:21552
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , FREQROL-A500
-
Parameters not covered in manual are displayed
Pr.168 indicates the inverter software version.Pr.169 indicates the inverter software subversion history. These two parameters are only used by the manufactu... More Details >>
- No:21532
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , FREQROL-E500
-
"8" display in offline auto tuning means forced stop by the operator. This means that you stopped operation before tuning completes. With this forced stop, ... More Details >>
- No:21527
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , FREQROL-A500
-
Since the inverter has only one voltage output (10 VDC) from terminal AM as the analog monitor, use the FR-EPA or FR-EPE option if you need two channels. The... More Details >>
- No:21501
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-B
-
What happens if reset occurs during operation?
This is because when the inverter restarts while the motor is coasting, an overcurrent trip can occur during the restart process. However, the recent types o... More Details >>
- No:21477
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-A024 , FREQROL-E500 , FREQROL-V200 , FREQROL-A200 , FREQROL-A100 , FREQROL-U100 , Common
141-150 of Total 1368