Blinking of the "RUN" LED on the panel suggests that the frequency command may not be input. Create a frequency setting data as for the forward rotation comm... More Details >>
Proportional band of multiple inverters
By importing the operation frequency from the AM terminal (analog output) of the first inverter to the FR-FH (ratio setter), the operation command which is p... More Details >>
FR Configurator SW3 (CC-Link Seamless)
It cannot be opened because FR Configurator SW3 and FR Configurator SW3 (CC-Link Seamless) are not compatible. More Details >>
Configure the same setting as the SF-HRCA. Configure the same setting as the SF-HRCA. A700, E700, D700, F700PJ: Pr.71 = 50F700P, F700: Pr.71 = 1 (Reference) ... More Details >>
PDF data is available free of charge with free registration from the Mitsubishi Electric FA Global Website. All the printed materials are available for a fee. More Details >>
SW1DND-FRC2 (FR Configurator2)
Yes. More Details >>
Installation necessity of a DC reactor
A DC reactor connection is required under the following conditions. - Inverter capacity is 75K or higher - Motor capacity is 75 kW or higher. If any of the a... More Details >>
The FR-E7TR does not have the terminal for the SC and it cannot be used with the FR-E700-SC. More Details >>
Circuit type of the FR-D700W/FR-E700W...
It is single-phase bridge (smoothing capacitor, double voltage rectification). More Details >>
Yes, it does, however, it does not acquire the certification of the BACnet association standard. More Details >>