Under Real sensorless vector control, the maximum wiring length is 500 m. Under Vector control with encoder, the maximum wiring length is 100 m. More Details >>
- No:21133
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , FREQROL-A700
-
Yes, it is. More Details >>
- No:21213
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
When the second torque limit is used, the settings of Pr.816 and 817 are valid. More Details >>
- No:21218
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
System environment variable of the Modbus-RTU communication
They are not received during the operation. They are also not received if the command authority does not exist in the communication. When they are executed i... More Details >>
- No:21223
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
Noise effect of CC-Link IE communication
The same test as CC-Link is performed, and we confirmed no problem. More Details >>
- No:21226
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
Checking bit state by CC-Link communication
Because the H0F monitor only observes the ON/OFF of the hardware, it cannot be checked. More Details >>
- No:21230
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
Wiring of CC-Link communication cable
The communication is established if DA, DB, and DG are connected each other. More Details >>
- No:21239
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
Earthing (grounding) of FR-A7NC (E kit)
There is no problem, however, earthing (grounding) from each FG terminal is recommended to avoid the influence of noises. More Details >>
- No:21240
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
When the built-in brake resistor is used, the regenerative brake duty is as follows:200 V 0.4K to 3.7K: 3%, 5.5K to 7.5K: 2%400 V 0.4K to 7.5K: 2 % The capac... More Details >>
- No:21273
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , FREQROL-A700
-
It can be driven by connecting single-phase 200 V to the terminals R and S. In this case, the load current must be one-third or less of the inverter rated cu... More Details >>
- No:21282
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , FREQROL-E700