FAQ


FAQAbout Products
FAQ
Keyword Search
Drive Products
-
FREQROL-A800(144)
FREQROL-F800(89)
FREQROL-A700(352)
FREQROL-D700(261)
FREQROL-E700(394)
FREQROL-F700(296)
FREQROL-F700P(295)
FREQROL-F700PJ(252)
FREQROL-A024(40)
FREQROL-A100(21)
FREQROL-A200(32)
FREQROL-A500(123)
FREQROL-B(10)
FREQROL-E500(85)
FREQROL-F400(2)
FREQROL-F500(15)
FREQROL-S500(11)
FREQROL-U100(16)
FREQROL-V200(52)
FREQROL-Z020(1)
FREQROL-Z024(2)
FREQROL-Z100(2)
FREQROL-Z123(2)
FREQROL-Z200(3)
FREQROL-Z300(2)
SC-A(12)
Engineering Software(43)
Magnet motor drive(9)
Peripheral devices(7)
Options(129)
Plug-in Options(30)
Others(53)
FAQ within [ Drive Products ]
-
PID control of CC-Link communication
When performing the PID control by CC-Link communication, the X14 signal is disabled. More Details >>
- No:21233
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
Wiring of CC-Link communication cable
The communication is established if DA, DB, and DG are connected each other. More Details >>
- No:21239
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
Earthing (grounding) of FR-A7NC (E kit)
There is no problem, however, earthing (grounding) from each FG terminal is recommended to avoid the influence of noises. More Details >>
- No:21240
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
The output current monitor of the inverter displays the output current effective value of the three phases measured by the current sensor. It does not displa... More Details >>
- No:21373
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-E500
-
Operation of the motor with a brake
For the general-purpose inverter, the motor stop cannot be detected accurately because the actual motor speed from a motor is not input. In general, the RUN ... More Details >>
- No:21375
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-A500
-
The instantaneous power failure error occurs when the power is turned ON instantaneously (within 100 ms) after the power is turned OFF. When the motor is coa... More Details >>
- No:21388
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL
-
Notes on using single-phase 200 V
With the single-phase 200 V input specifications, the input cable current increases. Therefore, choose larger power supply capacity and NF/MC than three-phas... More Details >>
- No:21406
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-E500
-
Installing reactor for suppressing harmonics
You can connect multiple inverters to a single reactor. In this case, the load seems to be light from the reactor unless all of the inverters are rotating an... More Details >>
- No:21410
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , Options
-
Indication of potentiometer on operation panel
The potentiometer on the operation panel is initially calibrated so that the maximum indication is slightly over 60 Hz with the potentiometer turned to the m... More Details >>
- No:21427
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-E500
-
1. As the measurement condition is unknown, the possible cases are as follows: - If you measured the current on the input side of the inverter, since the cu... More Details >>
- No:21457
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL
151-160 of Total 1368