FAQ within [ Drive Products ]
-
Because the inverter status reading is stopped by the processing such as PLC in the inverter when the main circuit turns ON. It is stopped for approximately ... More Details >>
- No:20873
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , Plug-in Options
-
It depends on machine specifications. It depends on the accuracy of the line speed input and parameter setting of material thickness. More Details >>
- No:20927
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL
-
Under Real sensorless vector control, the maximum wiring length is 500 m. Under Vector control with encoder, the maximum wiring length is 100 m. More Details >>
- No:21133
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , FREQROL-A700
-
They are not insulated. More Details >>
- No:21182
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , FREQROL-E700
-
It is available on request as a dedicated product. Contact your sales representative. More Details >>
- No:21183
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , FREQROL-E700
-
The noise amount does not change because the carrier frequency does not change. More Details >>
- No:21198
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
There is no regulation value. Use the inverters in the environment without corrosive gas. More Details >>
- No:21201
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
System environment variable of the Modbus-RTU communication
It decelerates and stops. The operation is the same as the one when the Bit of forward rotation command and reverse rotation command are turned OFF. More Details >>
- No:21222
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
Noise effect of CC-Link IE communication
The same test as CC-Link is performed, and we confirmed no problem. More Details >>
- No:21226
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
Pr.38 of the E500 corresponds to Pr.125 (Terminal 2 frequency setting gain frequency) of D700. Pr.39 of the E500 corresponds to Pr.126 (Terminal 4 frequency ... More Details >>
- No:21254
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , FREQROL-D700