FAQ within [ Drive Products ]
-
A plug-in option cannot be installed on the FREQROL-A024 series. If you need a plug-in option's function, use other series of inverters such as the FREQROL-A... More Details >>
- No:21608
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , FREQROL-A024
-
General-purpose magnetic flux control
Almost same control method. This control also performs vector calculation and divides the inverter's output current into an excitation current and into a tor... More Details >>
- No:21620
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , FREQROL-A024
-
Rated capacity related to harmonic suppression guidelines
The usual inverter input current is determined not by the inverter capacity but by the motor capacity (motor load).Therefore, the input side capacity is not ... More Details >>
- No:21961
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , Others
-
Set the parameters below. For other parameters, keep the initial settings.1. Set Pr.122 (Communication check time interval) to other than "0". ("9999" is OK.... More Details >>
- No:21986
- Release Date:2018/08/22 16:30
- Category: Engineering Software
-
Refer to the following points.For fan pump -> Square torqueFor general-purpose machine (for example, transport, elevation) -> Constant-torque type More Details >>
- No:22048
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-A500
-
With the FREQROL-U100 series, pressing and holding the [SET] switches to the current monitor. More Details >>
- No:22073
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-U100
-
When connecting to the P/+, the current flows in the inrush circuit at the regenerative driving. This regenerative current may generate losses in the inrush ... More Details >>
- No:20815
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL
-
It is less than 1 mA. More Details >>
- No:20836
- Release Date:2018/08/22 16:24
- Category: Options
-
Vector control cannot be selected unless Pr.862 is set to 1. Only the first motor is supported in the motor setting of FR Configurator2. More Details >>
- No:20847
- Release Date:2018/08/22 16:24
- Category: Engineering Software
-
Yes, it does, however, it does not acquire the certification of the BACnet association standard. More Details >>
- No:20863
- Release Date:2018/08/22 16:24
- Category: FREQROL-F800