FAQ within [ Drive Products ]
-
The anti-sway control can be performed with the inverter alone. More Details >>
- No:20930
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL
-
The CC-Link communication can be supported by using option FR-A7NC E kit. More Details >>
- No:21031
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL
-
Yes, the plug-in option board can also be read. More Details >>
- No:21032
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL
-
An earth plate permanently installed in the 700 series is included as an option for the 800 series because of the change of the shape of the circuit board. More Details >>
- No:21035
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL
-
Yes. More Details >>
- No:21047
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL
-
The noise amount does not change because the carrier frequency does not change. More Details >>
- No:21198
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
System environment variable of the Modbus-RTU communication
It decelerates and stops. The operation is the same as the one when the Bit of forward rotation command and reverse rotation command are turned OFF. More Details >>
- No:21222
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
Monitor value at CC-Link communication
The data of output frequency, output current, and output voltage are retained at alarm occurrence, but other monitors are not. More Details >>
- No:21235
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
Remote input signal of CC-Link communication
When the communication error occurs, the input signal status is not retained, and all the bits turn OFF. When the communication establishes again, the bit tu... More Details >>
- No:21237
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
They are insulated. More Details >>
- No:21242
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
11-20 of Total 1368