FAQ within [ Drive Products ]
-
The output current monitor of the inverter displays the output current effective value of the three phases measured by the current sensor. It does not displa... More Details >>
- No:21373
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-E500
-
Operation of the motor with a brake
For the general-purpose inverter, the motor stop cannot be detected accurately because the actual motor speed from a motor is not input. In general, the RUN ... More Details >>
- No:21375
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-A500
-
Countermeasure against the harmful effect on model selection and other devices
Harmful elements that may affect other devices through the input side of the inverter include noise and harmonics. Harmonics can be reduced by inserting the ... More Details >>
- No:21396
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL
-
The FR-PU02-1 cannot be used with the FR-B3 series inverters. Use the FR-DU04 or FR-PU04. More Details >>
- No:21408
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-B
-
To conform to the EMC Directive when exporting to an EU country, install the filter that conforms to the EMC Directive on the inverter, and take measures acc... More Details >>
- No:21414
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-A500
-
Relationship between frequency and load current
If the load is heavy and the output current is higher than the control value, you can adjust Pr.22 (Stall prevention operation level) to trigger the stall pr... More Details >>
- No:21450
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL
-
Difference between FR-AU01 and AU01A
The major changes from FR-AU01 to FR-AU01A include 1. Case material and 2. Lead wire terminal process method. The FR-AU01A has a backward compatibility with ... More Details >>
- No:21452
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , Options
-
This error depends on the application and the cause is unknown. (The runtime error '31037' is not returned from this application but from the OS (Windows).) ... More Details >>
- No:21495
- Release Date:2018/08/22 16:27
- Category: Engineering Software
-
Energy saving and power supply capacity of inverter
Energy saving is achieved by switching from the commercial power supply to the inverter to operate the motor. When the inverter reduces motor speed, it also... More Details >>
- No:21498
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , Others
-
What is the replacement of the FR-BOL?
We do not offer a replacement product for the FR-BOL (noise reduction reactor). Since the FR-A100E is a low-noise type inverter, the motor noise is suppresse... More Details >>
- No:21500
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , Options