FAQ within [ Drive Products ]
-
PHS does not cause the inverter to malfunction.On the contrary, if you use PHS near an inverter or motor, communication over PHS may become noisy or even get... More Details >>
- No:22018
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
Using shielded wires for frequency meter connection
Connect the shield to the terminal SD. More Details >>
- No:22034
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-A500
-
Just by adding this option, encoder pulses connected to the inverter or option are output.You can also divide the pulse train output. More Details >>
- No:22062
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-V200
-
1. As the reactor (FR-HCL) is connected when connecting the FR-HC, do not connect the FR-BAL. 2. The noise filter can be connected to the input side of the F... More Details >>
- No:22101
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , Options
-
Check if the communication setting parameters (Pr.117 to Pr.124) are set to the same values between the inverter and personal computer.Note that communicatio... More Details >>
- No:22105
- Release Date:2018/08/22 16:31
- Category: Inverters-FREQROL , FREQROL-A500
-
- Both 200 V and 400 V can be used only with the capacity 22 kW or higher. - The rated current (capacity) is derated. (For the detail, refer to the Instructi... More Details >>
- No:20802
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , Options
-
Not required. Select it according to the capacity of the vector motor used. More Details >>
- No:20804
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , Options
-
Yes. More Details >>
- No:20810
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , Others
-
No, you cannot use the safety stop function. More Details >>
- No:20817
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , FREQROL-B
-
Combination of the FR-F800 and MM-EFS
Yes, it can. Set "12" or "112" to the MM-EFS capacity used for Pr.80 (Motor capacity) and Pr.998 (PM parameter initialization). More Details >>
- No:20820
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , FREQROL-F800