FAQ within [ Drive Products ]
-
If multiple line noise filters are wound without clearance between them, the noise reduction effect corresponding to the number of filters cannot be obtained... More Details >>
- No:22087
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , Options
-
Motor rated rotations per minute
The inverter is capable of output up to the maximum frequency. It is the matter of whether the motor used support high-speed operation. In the situation you ... More Details >>
- No:22099
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
Operation at external operation/stop
It is recommended to turn OFF the start signals (STF and STR) when stopping the inverter.In this case, it is not probable that the motor rotates due to a cal... More Details >>
- No:22102
- Release Date:2018/08/22 16:31
- Category: Inverters-FREQROL , FREQROL-E500
-
Two digits after the decimal point are rounded off. 28.139 Hz is rounded down to 28.13 Hz. More Details >>
- No:20812
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , Plug-in Options
-
No, it cannot. Purchase IQ-Works2 or FR Configurator2. Upgrading to from IQ-Works to IQ-Works2 is for a fee. More Details >>
- No:20829
- Release Date:2018/08/22 16:24
- Category: Engineering Software
-
For the 200 V type, the leakage current at the delta connection is 5 mA. For the 400 V type, it is 10 mA. More Details >>
- No:20835
- Release Date:2018/08/22 16:24
- Category: Options
-
Frequency setting by the CC-Link
When the frequency setting value is written by the CC-Link to EEPROM, the frequency setting value set with the PU (operation panel) is changed. More Details >>
- No:20851
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL
-
Circuit type of the FR-D700W/FR-E700W in the harmonics suppression guideline
It is single-phase bridge (smoothing capacitor, double voltage rectification). More Details >>
- No:20864
- Release Date:2018/08/22 16:24
- Category: FREQROL-E700
-
The FR-E7TR does not have the terminal for the SC and it cannot be used with the FR-E700-SC. More Details >>
- No:20865
- Release Date:2018/08/22 16:24
- Category: FREQROL-E700
-
Yes, because the same enclosure cut dimensions is adopted. More Details >>