FAQ within [ Drive Products ]
-
Yes, it is. More Details >>
- No:20968
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , Options
-
It is not grounded to the enclosure due to the resin coating. More Details >>
- No:21122
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , Options
-
FR Configurator SW3 (CC-Link Seamless)
It is supports FR Configurator Ver.4.90 or later. More Details >>
- No:21173
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , Engineering Software
-
Yes, they can. More Details >>
- No:20856
- Release Date:2018/08/22 16:24
- Category: FREQROL-A800
-
Number of terminals: Same input terminals as the A700 series, and the following two terminals are added. Safety: SI1, SI2, SIC 24 V power supply: +24 * The t... More Details >>
- No:21099
- Release Date:2018/08/22 16:25
- Category: FREQROL-A800
-
It is not covered. More Details >>
- No:21132
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , Others
-
It is approximately 500,000 times in the rated specification. More Details >>
- No:21202
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
The inverter alarm "OV3" occurs when the main circuit DC voltage inside the inverter goes higher than the preset value due to the regenerative power returned... More Details >>
- No:21438
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-A024
-
Power factor of inverter drive
Under 100% load, the power factors of the AC and DC reactors are 90% and 95%, respectively. For a line with no inverter control, use a power factor correctio... More Details >>
- No:21934
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
How can I have the motor coast to stop?
You can use the following two methods:1. Turn ON MRS at the same time when STF turns OFF.2. Set Pr.10 = 60 Hz, Pr.11 = 0 sec, and Pr.12 = 0% (when the invert... More Details >>
- No:21967
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
21-30 of Total 1368