FAQ


FAQAbout Products

FAQ
Keyword Search
Drive Products
-
FREQROL-A800(144)
FREQROL-F800(89)
FREQROL-A700(352)
FREQROL-D700(261)
FREQROL-E700(394)
FREQROL-F700(296)
FREQROL-F700P(295)
FREQROL-F700PJ(252)
FREQROL-A024(40)
FREQROL-A100(21)
FREQROL-A200(32)
FREQROL-A500(123)
FREQROL-B(10)
FREQROL-E500(85)
FREQROL-F400(2)
FREQROL-F500(15)
FREQROL-S500(11)
FREQROL-U100(16)
FREQROL-V200(52)
FREQROL-Z020(1)
FREQROL-Z024(2)
FREQROL-Z100(2)
FREQROL-Z123(2)
FREQROL-Z200(3)
FREQROL-Z300(2)
SC-A(12)
Engineering Software(43)
Magnet motor drive(9)
Peripheral devices(7)
Options(129)
Plug-in Options(30)
Others(53)
FAQ within [ Drive Products ]
-
When Pr.80 and Pr.81 are set to the value other than "9999", control other than V/F control is performed. For the FR-F700(P) FR-D700, and FR-F700PJ, Pr.81 is... More Details >>
- No:21259
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , FREQROL-E700 , FREQROL-D700 , FREQROL-A700 , FREQROL-F700 , FREQROL-F700P , FREQROL-F700PJ
-
After setting Pr.79 (Operation mode selection) to "2" and Pr.340 (Communication startup mode selection) to "10", reset the inverter (or power ON again) to st... More Details >>
- No:21256
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , FREQROL-E700 , FREQROL-A700 , FREQROL-F700 , FREQROL-F700P
-
Automatic restart after instantaneous power failure
The inverter restart operation is disabled at turn-OFF of the CS signal while a value other than "9999" (with restart) is set in Pr.57. The terminals CS and ... More Details >>
- No:21255
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , FREQROL-A700 , FREQROL-F700 , FREQROL-F700P
-
Power is supplied only to the control power supply, and thus this enables communication, parameter setting through the operation panel or an USB memory devic... More Details >>
- No:21097
- Release Date:2018/08/22 16:25
- Category: FREQROL-A800 , FREQROL-F800
-
No, the MT-BU5 is not available Use the FR-BU2 instead. More Details >>
- No:21076
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , Options , FREQROL-A800 , FREQROL-F800
-
Calculation of inverter acceleration and deceleration time
Refer to the Technical Sheet No.23 (Capacity Selection and Continuous Operation) for reference for selection. Optional capacity selection software is also pr... More Details >>
- No:22097
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-A500
-
You can check the fault records with Pr.544 (CC-Link extended setting) set to "12" for double setting.Set H74 for the instruction code and turn ON RYF. More Details >>
- No:21829
- Release Date:2018/08/22 16:29
- Category: Inverters-FREQROL , FREQROL-E700 , FREQROL-A700 , FREQROL-F700 , FREQROL-F700P
-
For low-speed operation, perform auto tuning and use (Advanced) magnetic flux vector control. More Details >>
- No:21810
- Release Date:2018/08/22 16:29
- Category: Inverters-FREQROL , FREQROL-E700 , FREQROL-A700 , FREQROL-F700 , FREQROL-F700P
-
1. Set Pr.162 to "10" (Frequency search at every start).2. You can ignore the setting if the motor excitation current is unknown. More Details >>
- No:21718
- Release Date:2018/08/22 16:29
- Category: Inverters-FREQROL , FREQROL-E700 , FREQROL-D700 , FREQROL-A700 , FREQROL-F700 , FREQROL-F700P , FREQROL-F700PJ
-
"8" display in offline auto tuning means forced stop by the operator. This means that you stopped operation before tuning completes. With this forced stop, ... More Details >>
- No:21527
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , FREQROL-A500
291-300 of Total 1368