FAQ within [ Drive Products ]
-
Real sensorless vector control
The FR-A700 supports Real sensorless vector control. More Details >>
- No:21714
- Release Date:2018/08/22 16:29
- Category: FREQROL-A700
-
Use Pr.C24 (Frequency setting voltage gain frequency built-in potentiometer). More Details >>
- No:21847
- Release Date:2018/08/22 16:29
- Category: FREQROL-E700
-
How can I have the motor coast to stop?
You can use the following two methods:1. Turn ON MRS at the same time when STF turns OFF.2. Set Pr.10 = 60 Hz, Pr.11 = 0 sec, and Pr.12 = 0% (when the invert... More Details >>
- No:21967
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
Frequency misalignment at current input
It seems that calibration of the current input is slightly incorrect.By using Pr.904 (Frequency setting current bias) and Pr.905 (Gain), you can calibrate th... More Details >>
- No:22014
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
Using shielded wires for frequency meter connection
Connect the shield to the terminal SD. More Details >>
- No:22034
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-A500
-
Setting Pr.37 to the machine speed at 60 Hz switches the frequency monitor to the rotations per minute monitor.Note that the speed setting must be input in a... More Details >>
- No:22072
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-E500
-
Inverter installation interchange attachment
Use the FR-A5AT02 as the intercompatibility attachment when upgrading from the FR-A220-3.7K to FR-A540-3.7K. More Details >>
- No:22095
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-A500
-
Replacement with the FR-B, B3 (A800 specification)
In the A800 base of the FR-B and FR-B3, the Easy setup wizard is not available. Thus, some functions are restricted. More Details >>
- No:20862
- Release Date:2018/08/22 16:24
- Category: FREQROL-B
-
The inverter is reset. More Details >>
- No:20869
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , FREQROL-E700
-
If Pr.361 = 0, the second terminal can be used as the line speed command when X114 is ON, and as the frequency setting value when X114 is OFF. If Pr.361 = 3,... More Details >>
- No:20891
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , FREQROL-A800