FAQ within [ Drive Products ]
-
EMC compliant filter terminal cover
The SF1258 has the terminal cover.Although the SF1259 to SF1263 do not have the terminal covers and their terminals are bare, rubber tubes to cover them are ... More Details >>
- No:21956
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , Options
-
When controlling motor with brake by inverter
Use the RUN signal to turn ON and OFF the brake.Using the MRS (output shutoff) signal to turn ON the brake shuts off the inverter's output and reduces influe... More Details >>
- No:21960
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
AC reactor and line noise filter wiring
Basically, either is OK.Both orders are electrically identical, but "1" is recommended since it is preferable to place the line noise filter close to the inv... More Details >>
- No:21964
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
Instantaneous power failure of facilities
1. If the start signal is present when the power and communication restore, the inverter starts operation. 2. Similarly to the above, if the start signal is ... More Details >>
- No:22093
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-E500
-
The resistor unit MT-BR5 manufactured in February 2016 or later has output terminal TH3 (NC contact) as a fault output terminal. More Details >>
- No:20816
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , Options
-
No, it cannot. Purchase IQ-Works2 or FR Configurator2. Upgrading to from IQ-Works to IQ-Works2 is for a fee. More Details >>
- No:20829
- Release Date:2018/08/22 16:24
- Category: Engineering Software
-
S-shape acceleration/deceleration of the FR-D700
It does not change even when General-purpose magnetic flux vector control is performed. Pr.3 is the inflection point of the S-shape. More Details >>
- No:20834
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , FREQROL-D700
-
The output turns OFF (0 mA) during the inverter reset. More Details >>
- No:20921
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , FREQROL-A800
-
The tension PI gain can be adjusted automatically by performing the tension PI gain tuning. More Details >>
- No:20923
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , FREQROL-A800
-
The internal transistor of the HC2 stops by turning on the SOF signal and stopping the converter. As a result, regenerative driving is not performed. However... More Details >>
- No:20941
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , Options
301-310 of Total 1353