FAQ within [ Drive Products ]
-
Setting value of Pr.72 (FR-B, B3 (A800 base))
For the normal type (FR-B3) is 2 KHz. For the low-noise type (FR-B3-N), 14.5 KHz. More Details >>
- No:20828
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , FREQROL-B
-
Amount of heat generated by the FR-V500L
It is the same as the one by the inverter whose capacity is one-rank higher than the FR-A500L series. More Details >>
- No:20854
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL
-
It is protected not by observing the temperature directly, but by estimating it from the current value, output frequency, and carrier frequency. More Details >>
- No:20871
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , FREQROL-A700
-
Yes. It can be carried out like under the dancer feedback speed control. More Details >>
- No:20885
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , FREQROL-A800
-
For output signals, up to 10 points (RXn2 to RXB) can be assigned. It is possible if the number of the importing signal points are within this range. More Details >>
- No:20943
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , Plug-in Options
-
Yes. More Details >>
- No:20986
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , Options
-
Combination of the FR-A800 and MM-BF
Select the models so that "MM - BF rated current value × 1.05 < FR-A820 rated output current value". More Details >>
- No:21000
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , FREQROL-A800
-
At power-ON, the signal turns ON for a moment to perform a converter initial reset. More Details >>
- No:21156
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , Options
-
Pr.59 is available in the products manufactured in October 1995 or later. Therefore, it cannot be read from the products manufactured before October 1995. More Details >>
- No:21170
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , FREQROL-A024
-
It is available. Insulate the raised wiring of T-phase. More Details >>
- No:21177
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , Options