FAQ


FAQAbout Products
FAQ
Keyword Search
Drive Products
-
FREQROL-A800(142)
FREQROL-F800(89)
FREQROL-A700(351)
FREQROL-D700(260)
FREQROL-E700(393)
FREQROL-F700(295)
FREQROL-F700P(294)
FREQROL-F700PJ(251)
FREQROL-A024(40)
FREQROL-A100(21)
FREQROL-A200(32)
FREQROL-A500(119)
FREQROL-B(9)
FREQROL-E500(84)
FREQROL-F400(2)
FREQROL-F500(15)
FREQROL-S500(11)
FREQROL-U100(16)
FREQROL-V200(51)
FREQROL-Z020(1)
FREQROL-Z024(2)
FREQROL-Z100(2)
FREQROL-Z123(2)
FREQROL-Z200(3)
FREQROL-Z300(2)
SC-A(12)
Engineering Software(41)
Magnet motor drive(9)
Peripheral devices(7)
Options(127)
Plug-in Options(30)
Others(53)
FAQ within [ Drive Products ]
-
Not available for the FR-E700-SC. For the 485 communication with the terminal block, use the standard FR-E700. More Details >>
- No:21130
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , Options , FREQROL-E700
-
It is set to "1" (cooling fan ON-OFF control enabled). More Details >>
- No:21131
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , FREQROL-F700PJ
-
It is 0.88 mm2 (AWG18), and 0.3 mm2 (AWG24) for the thermostat. More Details >>
- No:21147
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , Options
-
It bypasses (removes) high-frequency current due to switching that is output by the FR-HC2 to prevent it from being flown into the power supply system as a f... More Details >>
- No:21152
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , Options
-
Check the setting value of Pr.37 (Speed display). When the machine speed is set, Pr.811 is disabled. Change the setting to the rotation speed. More Details >>
- No:21161
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , FREQROL-A700
-
The initial value of Pr.78 (Reverse rotation prevention selection) of the MD-CX522 is "1" (reverse rotation is disabled). When performing forward rotation an... More Details >>
- No:21168
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
Pr.59 is available in the products manufactured in October 1995 or later. Therefore, it cannot be read from the products manufactured before October 1995. More Details >>
- No:21170
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , FREQROL-A024
-
They are not insulated. More Details >>
- No:21182
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , FREQROL-E700
-
EEPROM writing with the communication option
The writing from the parameter unit or operation panel is always ROM write regardless of the setting value of Pr.342. More Details >>
- No:21206
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
It is not output in the JOG operation mode. More Details >>
- No:21214
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
311-320 of Total 1353