FAQ within [ Drive Products ]
-
It can be performed by setting Pr.292 (Automatic acceleration/deceleration) to "8" and Pr.279 (Brake opening current) to 0%. More Details >>
- No:21186
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , FREQROL-E700 , FREQROL-A700
-
Torque control cannot be performed with the FR-E700 series. It is available with the FR-A700 and FR-V500 series. More Details >>
- No:21279
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , FREQROL-E700
-
The copy function of the parameter unit (FR-PU04) is not available. Setting each parameter again or using the convert function of FR Configurator (FR-SW3-SET... More Details >>
- No:21337
- Release Date:2018/08/22 16:27
- Category: FREQROL-E700
-
The operating environment of FA products
The following surrounding environment is common to all models. Surrounding air temperature: No problem. The inverters can be used in -10 to 50°C. Above sea l... More Details >>
- No:21386
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL
-
Selection method of the reactor
For the use of the 400 V class inverter, the surge voltage suppression filter FR-ASF is provided to suppress the surge voltage occurred at the motor terminal... More Details >>
- No:21389
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , Options
-
1. Choose the circuit breaker based on the inverter capacity. 2. Also, choose the brake resistor based on the inverter capacity. 3. Choose the AC reactor bas... More Details >>
- No:21425
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-A024
-
The RS485 communication is explained in the FREQROL-E500 Instruction Manual. This Instruction Manual is published on the member's page of Mitsubishi Electric... More Details >>
- No:21426
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-E500
-
The FM output is the 1440 Hz, 1 mA pulse train output at full scale. You can input to the programmable controller if it has a pulse train input. A68AD does n... More Details >>
- No:21439
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-A024
-
Details of zero current detection
1. The inverter also monitors the output current during DC injection brake operation in addition to normal operation. Therefore, zero current detection also ... More Details >>
- No:21481
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-A024
-
Countermeasure against the fault occurrence
When a CC-Link communication fault occurs, the option error (OP3) occurs on the inverter and the output is shut off, and the motor starts coasting. When usin... More Details >>
- No:21531
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , FREQROL-A500
311-320 of Total 1353