FAQ within [ Drive Products ]
-
Overshooting of the speed due to the acceleration/deceleration may be the cause. Overshooting is more likely to occur when the load inertia is too high. As a... More Details >>
- No:21216
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
When the torque is supposed as 100% at 60 Hz, the torque becomes 75 % at 80 Hz. (Under V/F control, the torque decreases when the frequency exceeds 60 Hz bec... More Details >>
- No:21284
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , FREQROL-E700 , FREQROL-D700 , FREQROL-A700 , FREQROL-F700 , FREQROL-F700P , FREQROL-F700PJ
-
The current monitor displays the average value of the three-phase current. The three-phase voltage is not incorporated for the voltage monitor. The output vo... More Details >>
- No:21376
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-A500 , FREQROL-E500
-
We recommend the "YM206RI 1 mA" analog ammeter. More Details >>
- No:21402
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , Options
-
1. Choose the circuit breaker based on the inverter capacity. 2. Also, choose the brake resistor based on the inverter capacity. 3. Choose the AC reactor bas... More Details >>
- No:21425
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-A024
-
We offer DC reactors from 0.4K and you can use it. You can use FR-BIF, FR-BSF, and FR-BEL together. More Details >>
- No:21461
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , Options
-
I want to shorten deceleration time of small capacity motor
You can use an inverter with a larger capacity than the motor. You cannot connect a brake resistor to the FR-E520-0.1K and 0.2K. With the FR-E520-0.1K or 0.2... More Details >>
- No:21463
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-E500
-
Countermeasure against harmonics
Perform calculation given in the harmonic suppression guidelines, and if the limit value is exceeded, you may also need to insert the ACL. Note that you cann... More Details >>
- No:21465
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , Options
-
I cannot answer clearly because the load is unknown. The operation cycle of operating for 10 seconds and stopping for 10 seconds is OK, but it is questionabl... More Details >>
- No:21474
- Release Date:2018/08/22 16:27
- Category: FREQROL-E500
-
Details of zero current detection
1. The inverter also monitors the output current during DC injection brake operation in addition to normal operation. Therefore, zero current detection also ... More Details >>
- No:21481
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-A024