FAQ within [ Drive Products ]
-
Monitor value at CC-Link communication
The data of output frequency, output current, and output voltage are retained at alarm occurrence, but other monitors are not. More Details >>
- No:21235
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
Pr.38 of the E500 corresponds to Pr.125 (Terminal 2 frequency setting gain frequency) of D700. Pr.39 of the E500 corresponds to Pr.126 (Terminal 4 frequency ... More Details >>
- No:21254
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , FREQROL-D700
-
Operation of the motor with a brake
For the general-purpose inverter, the motor stop cannot be detected accurately because the actual motor speed from a motor is not input. In general, the RUN ... More Details >>
- No:21375
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-A500
-
The constant-torque motor and vector motor are the induction motors, which consist of the stator core, gap, and rotor core. For the constant-torque motor, th... More Details >>
- No:21378
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , Others
-
Functions available when using inverter on CC-Link
You can use the regular terminal block wire functions during CC-Link operation. Set Pr.338 (Operation command source) and Pr.339 (Speed command source) to e... More Details >>
- No:21393
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-A500
-
Direct driven start by power supply
The warning "Do not use a magnetic contactor on the inverter input for frequent starting/stopping of the inverter." is indicated in the precautions at the be... More Details >>
- No:21458
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-E500
-
I want to shorten deceleration time of small capacity motor
You can use an inverter with a larger capacity than the motor. You cannot connect a brake resistor to the FR-E520-0.1K and 0.2K. With the FR-E520-0.1K or 0.2... More Details >>
- No:21463
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-E500
-
Inverter operation against power supply voltage drop
Depending on the load current, undervoltage protection (UVT) or instantaneous power failure protection (IPF) is triggered to shut off the inverter output, an... More Details >>
- No:21471
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-A500
-
Number of years of service life designated by law
The number of years of service life of the inverter is not designated by law. More Details >>
- No:21497
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , Others
-
What happens if the supplied reactor and outside box are not used?
Harmonics cannot be suppressed (controlled) correctly and noise cannot be removed. Be sure to connect the supplied reactor and outside box to the inverter. More Details >>
- No:21557
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , Options