FAQ within [ Drive Products ]
-
Installing frequency setting potentiometer
When you are inputting analog signals, install the potentiometer within 30 m from the inverter. (Refer to "Precaution on Selection and Operation" on the cat... More Details >>
- No:22051
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
Frequency does not rise with blower
Our suggestion is to adjust the following parameters:1. Set Pr.14 = 0. If the V/F pattern for variable-torque load (Pr.14 = 1) is used, the current may incre... More Details >>
- No:22060
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-F500
-
All parameters returned to initial values
The parameters of the A500 series are stored in the EEPROM.The reason why all parameters returned to the initial values is considered that you may have opera... More Details >>
- No:22066
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-A500
-
With the FREQROL-U100 series, pressing and holding the [SET] switches to the current monitor. More Details >>
- No:22073
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-U100
-
Pulse frequency characteristics of terminal FM
The terminal FM output pulse is directly proportional to the inverter output frequency.With the initial setting, 1440 pulses/sec are output at 60 Hz (Pr.55),... More Details >>
- No:22080
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
Instantaneous power failure of facilities
1. If the start signal is present when the power and communication restore, the inverter starts operation. 2. Similarly to the above, if the start signal is ... More Details >>
- No:22093
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-E500
-
Not required. Select it according to the capacity of the vector motor used. More Details >>
- No:20804
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , Options
-
Vector control cannot be selected unless Pr.862 is set to 1. Only the first motor is supported in the motor setting of FR Configurator2. More Details >>
- No:20847
- Release Date:2018/08/22 16:24
- Category: Engineering Software
-
For the V/F control and Advanced magnetic flux vector control, the FR-A800 stops only by Pr.1103 Deceleration time at emergency stop. Pr.815 is not affected. More Details >>
- No:20860
- Release Date:2018/08/22 16:24
- Category: FREQROL-A800
-
Replacement with the FR-B, B3 (A800 specification)
In the A800 base of the FR-B and FR-B3, the Easy setup wizard is not available. Thus, some functions are restricted. More Details >>
- No:20862
- Release Date:2018/08/22 16:24
- Category: FREQROL-B