FAQ within [ Drive Products ]
-
They are not output while the motor is coasting even under Vector control. More Details >>
- No:21158
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , FREQROL-A700
-
FR-FS-0.4K: 35 W, FR-FS-0.8K: 65 W, Noise filter: 4 W More Details >>
- No:21165
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
FR Configurator SW3 (CC-Link Seamless)
Pr.77 and 79 cannot be changed via CC-Link communication. More Details >>
- No:21174
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , Engineering Software
-
Keep a clearance of "minimum 10cm each on top and bottom and minimum 5cm each on right and left". More Details >>
- No:21178
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , Options
-
Watt-hour meter clear and operation hour meter clear
The values are set to Pr.170 and 171 when the monitor value of cumulative power and actual operation time overflows. It does not affect the operation. Use it... More Details >>
- No:21197
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
It is 1 mA as the 700 series. More Details >>
- No:21204
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
Because the multi-speed terminal is disabled, it does not operate in multi-speed. More Details >>
- No:21205
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
EEPROM writing with the communication option
The writing from the parameter unit or operation panel is always ROM write regardless of the setting value of Pr.342. More Details >>
- No:21206
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
Communication EEPROM write selection (Pr.342)
They are cleared by the RES signal from the external terminals or inverter reset from the communication. More Details >>
- No:21221
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
Writing set frequency by CC-Link communication
No error will occur because up to 400 Hz that is the upper limit of the setting range can be written. More Details >>
- No:21229
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
371-380 of Total 1354