FAQ within [ Drive Products ]
-
Since the Advanced magnetic flux vector control method uses slip compensation to compensate the frequency, the value is not shown as exactly 60 Hz.For V/F co... More Details >>
- No:21807
- Release Date:2018/08/22 16:29
- Category: Inverters-FREQROL , FREQROL-E700 , FREQROL-A700
-
I want to display the speed on an analog meter.
As the inverter does not display the speed in m/min, let us explain using the speed display in r/min. In this case, set Pr.52 to "6" (operation panel display... More Details >>
- No:21944
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-A500
-
Short-circuiting frequency setting terminals
You can short-circuit the terminals 10 and 2.If you are considering to perform operation at the maximum frequency, consider using the high-speed command RH o... More Details >>
- No:21951
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
Speed 2 operation with potentiometer on operation panel
Yes. Set parameters as below.For FR-E500Set Pr.79 =3, and Pr.146= 0.Multi-speed is prioritized.For FR-S500Set Pr.79 = 3, and Pr.53 = 1.Multi-speed is priorit... More Details >>
- No:21963
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-E500 , FREQROL-S500
-
Imbalanced input side power supply
1. Power supply voltage phase imbalance toleranceMitsubishi inverter's input power supply voltage phase imbalance tolerance is ±3%.If the phase imbalance exc... More Details >>
- No:21987
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
Using shielded wires for frequency meter connection
Connect the shield to the terminal SD. More Details >>
- No:22034
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-A500
-
Inverter outline dimension CAD data
The outline dimension diagram is found on the member's page of Mitsubishi Electric FA Global Website.Contact our sales personnel for details on the programma... More Details >>
- No:22053
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-E500
-
The following version or later is supported for Windows 8. MR Configurator2, 1.20W or later More Details >>
- No:23633
- Release Date:2018/09/14 15:10
- Category: Servo Support Software
-
FR-A800 "Parameter for the communication setting"
These parameters are used for the communication compatible with the communication protocol of the Ethernet IP of the HMS optional circuit board (A8NEIP_2P). More Details >>
- No:20824
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , FREQROL-A800
-
It indicate that the actual number of connectable units differs depending on the master side specification although the maximum number of connectable units o... More Details >>
- No:20839
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , FREQROL-A800