JIS standard for the inverter is not established. It is required to check whether the whole machine including the inverter is compliant with JIS standard. More Details >>
- No:21023
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL
-
No, it is unavailable because the waterproof performance of the FR-A846 is lost when the operation panel is removed. More Details >>
- No:21039
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL
-
The setting is enabled at the Y24 start-up. The frequency cannot be changed when Y24 is always ON. Turn ON Y24 when writing a frequency. More Details >>
- No:21048
- Release Date:2018/08/22 16:25
- Category: FREQROL-A800 , FREQROL-F800
-
The specifications are the same. The same cable gauge is available. More Details >>
- No:21052
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL
-
The leakage current is 1 mA because the circuit constant in the EMC filter of A720-0.4K and 0.75K are different. More Details >>
- No:21120
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , FREQROL-A700
-
Yes, it can. When the FR-A7NF is installed, the CS terminal is disabled. Assign the CS terminal function to other input terminals by setting the parameter. B... More Details >>
- No:21121
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , Plug-in Options
-
Under Real sensorless vector control, the maximum wiring length is 500 m. Under Vector control with encoder, the maximum wiring length is 100 m. More Details >>
- No:21133
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , FREQROL-A700
-
Check that not only the current but also the various elements of the fuse such as cut-off speed and life are equivalent to those of the recommended product. More Details >>
- No:21153
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , Options
-
The following reasons are possible. - The signal of Z phase does not exist. (It is not returned normally.) - The setting of Pr.359 encoder rotation direction... More Details >>
- No:21162
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , FREQROL-A700
-
It is compatible with the -R type FR-S500. (It is not compatible with the FR-S500 without -R because it does not have the PU connector and thus cannot be con... More Details >>
- No:21175
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , Engineering Software