FAQ within [ Drive Products ]
-
Connecting ammeter to output side
Yes. Use a moving-iron type ammeter. However, if the carrier frequency exceeds 5 kHz, do not use that meter since an overcurrent losses produced in the inter... More Details >>
- No:21681
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , FREQROL-E700 , FREQROL-D700 , FREQROL-A700 , FREQROL-F700 , FREQROL-F700P , FREQROL-F700PJ
-
The total wiring length is as follows: 100 m + (20 m × 5) = 200m. More Details >>
- No:21144
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , FREQROL-E700 , FREQROL-D700 , FREQROL-A700 , FREQROL-F700 , FREQROL-F700P , FREQROL-F700PJ
-
Up to 64 (slave stations). The number of connectable units differs depending on the master station. More Details >>
- No:20857
- Release Date:2018/08/22 16:24
- Category: FREQROL-A800 , FREQROL-F800
-
The filtering effect is higher as the cable is wound more.However, if the cable is wound more than 4T on the inverter output side, since the inverter's outpu... More Details >>
- No:22064
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , Options
-
Control wire of FR-HC RDY signal
The contact between the terminals RDY and SE is open collector output.Operation is:Normal: Non-conductiveFault: Conductive More Details >>
- No:22017
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , Options
-
Power factor improving reactor
Your understanding about the AC and DC reactors is correct. For the harmonics suppression effect obtained by using both types of reactors, refer to the table... More Details >>
- No:21994
- Release Date:2018/08/22 16:30
- Category: Options
-
Regenerative overvoltage protection (E.OVT).This error occurs when the regenerative power returns from the motor to the inverter (for example, during deceler... More Details >>
- No:21991
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-F400
-
The surface temperature of approximately 70?C is OK.The following shows the MM-CF352 frame temperature for reference.(Actual temperature rise depends on how ... More Details >>
- No:21988
- Release Date:2018/08/22 16:30
- Category: Magnet motor drive
-
Use Pr.125 (Terminal 2 frequency setting gain frequency). More Details >>
- No:21913
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-E700 , FREQROL-D700 , FREQROL-A700 , FREQROL-F700 , FREQROL-F700P , FREQROL-F700PJ
-
You can start/stop operation, set the frequency, read/write parameters, and monitor the inverter via CC-Link communication. More Details >>
- No:21901
- Release Date:2018/08/22 16:29
- Category: Inverters-FREQROL , FREQROL-E700 , FREQROL-A700 , FREQROL-F700 , FREQROL-F700P