S-shape acceleration/deceleration of ...
It does not change even when General-purpose magnetic flux vector control is performed. Pr.3 is the inflection point of the S-shape. More Details >>
Safety stop function of the FR-E700/F...
Up to two. More Details >>
Relationship between undervoltage war...
When an instantaneous power failure occurs and the inverter's bus voltage drops below the standard value, it outputs an undervoltage warning and stops its ou... More Details >>
The inverter overcurrent shut-off fault indication E.OC1, E.OC2, or E.OC3 is not only displayed when the inverter output current reaches approximately 200% o... More Details >>
If Pr.79 = 3, PU and EXT turn ON. Switching between PU and EXT is not available. Turn the setting dial to set the frequency and press the SET key to accept it. More Details >>
Error "E.UVT" (undervoltage protection)
The possible causes of the error UVT are as follows.- Low power supply voltage - Insufficient power supply capacity - Damage or failure Check the power suppl... More Details >>
Frequency setting by the CC-Link
When the frequency setting value is written by the CC-Link to EEPROM, the frequency setting value set with the PU (operation panel) is changed. More Details >>
Range of possible frequencies that ca...
To prevent gear wear and bearing failures due to inadequate lubrication for oil lubrication-type models (GM-D and LJ), restrictions are placed on the frequen... More Details >>
The response delay time is 10 ms normally and 100 ms at startup. More Details >>
Difference between actual gear ratio ...
There are two types of gear ratios for Mitsubishi Geared Motors: nominal gear ratio and actual gear ratio. Nominal gear ratios are represented using integers... More Details >>