FAQ within [ Drive Products ]
-
It is for the HIV cable. More Details >>
- No:20850
- Release Date:2018/08/22 16:24
- Category: Options
-
Yes. Use the coated model, FR-A8NC-60. More Details >>
- No:20892
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL
-
Difference in the monitor function
The same value is displayed in the initial setting. When negative output is enabled by setting "0" to Pr.290 (Monitor negative output selection), there are f... More Details >>
- No:20938
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL
-
The acceleration time is 60 Hz and 5 seconds, and deceleration time is 60 Hz and 60 seconds. More Details >>
- No:21166
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
No. During JOG operation, deceleration stop is performed even though Pr.250 is set. More Details >>
- No:21199
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
The standby power of the FR-F700PJ series (with filterpack) is registered in member's page of Mitsubishi Electric FA Global Website. Refer to the Technical N... More Details >>
- No:21210
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
It is fundamentally the same as the conventional model. Considering the recent safety awareness growth, we decided to start supporting it from the FR-HC2. Be... More Details >>
- No:21212
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
Speed command by CC-Link communication
It is not possible when the speed command is communication. More Details >>
- No:21232
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
Wiring of CC-Link communication cable
The communication is established if DA, DB, and DG are connected each other. More Details >>
- No:21239
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
Wire length between inverter and motor
1. Wiring length between the inverter and the motor should be 500 m or less. For 0.75 kW or lower motors, the following relationship is true: Capacity... More Details >>
- No:21392
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL
31-40 of Total 1353