prev 4 / 137page next
  • FR-A846

    No, it is unavailable because the waterproof performance of the FR-A846 is lost when the operation panel is removed. More Details >>

  • Torque monitoring

    Setting a smaller value in Pr.1106 (Torque monitor filter) improves the response because the filter time constant for the torque monitoring becomes smaller, ... More Details >>

  • MT-BU5

    No, the MT-BU5 is unavailable because it is the conventional model. Use the FR-BU2. More Details >>

  • Terminal block

    The specifications are the same. The same cable gauge is available. More Details >>

  • FR-HC2

    The power of MC1 is supplied from the terminals across R2 and S2 of the outside box. Either phase of R2 or S2 may be lost. More Details >>

  • FR-FS

    The acceleration time is 60 Hz and 5 seconds, and deceleration time is 60 Hz and 60 seconds. More Details >>

  • MD-CX522

    The initial value of Pr.78 (Reverse rotation prevention selection) of the MD-CX522 is "1" (reverse rotation is disabled). When performing forward rotation an... More Details >>

  • FR-CVL

    Keep a clearance of "minimum 10cm each on top and bottom and minimum 5cm each on right and left". More Details >>

  • FR-B3

    The carrier frequency for the FR-B3 is 2 kHz. For the low noise type FR-B3-N, it is 14.5 kHz. More Details >>

  • FR-HC2

    It is fundamentally the same as the conventional model. Considering the recent safety awareness growth, we decided to start supporting it from the FR-HC2. Be... More Details >>

31-40 of Total 1368