FAQ


FAQAbout Products
FAQ
Keyword Search
Drive Products
-
FREQROL-A800(144)
FREQROL-F800(89)
FREQROL-A700(352)
FREQROL-D700(261)
FREQROL-E700(394)
FREQROL-F700(296)
FREQROL-F700P(295)
FREQROL-F700PJ(252)
FREQROL-A024(40)
FREQROL-A100(21)
FREQROL-A200(32)
FREQROL-A500(123)
FREQROL-B(10)
FREQROL-E500(85)
FREQROL-F400(2)
FREQROL-F500(15)
FREQROL-S500(11)
FREQROL-U100(16)
FREQROL-V200(52)
FREQROL-Z020(1)
FREQROL-Z024(2)
FREQROL-Z100(2)
FREQROL-Z123(2)
FREQROL-Z200(3)
FREQROL-Z300(2)
SC-A(12)
Engineering Software(43)
Magnet motor drive(9)
Peripheral devices(7)
Options(129)
Plug-in Options(30)
Others(53)
FAQ within [ Drive Products ]
-
Accuracy of inverter terminal FM
The pulses output from the inverter terminal FM are not completely synchronized with the inverter output frequency. The pulse circuit from the terminal FM an... More Details >>
- No:21516
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL
-
Installing contactor on input side
It is not recommended to install a contactor on the input side and connect the auxiliary contact to the terminal STF of the inverter for the following reason... More Details >>
- No:21533
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL
-
Inverter 200 V input and 400 V output
We do not have an inverter that directly takes 200 V input and generates 440 V output. Therefore, as you mention, use a 400 V class inverter by boosting the ... More Details >>
- No:21971
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
Motor rated rotations per minute
The inverter is capable of output up to the maximum frequency. It is the matter of whether the motor used support high-speed operation. In the situation you ... More Details >>
- No:22099
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
When connecting to the P/+, the current flows in the inrush circuit at the regenerative driving. This regenerative current may generate losses in the inrush ... More Details >>
- No:20815
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL
-
Yes, they are. More Details >>
- No:20877
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL
-
Yes. When Pr.9 = 0, turning is performed with the inverter rated current. Always set the rated motor current. More Details >>
- No:20897
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL
-
The count is resumed from 0. Thus, the times of the overflow is reset. More Details >>
- No:20902
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL
-
Yes, it is preferred. The accuracy becomes worse when the gap between the setting value and actual value increases. More Details >>
- No:20932
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL
-
Difference in the monitor function
The same value is displayed in the initial setting. When negative output is enabled by setting "0" to Pr.290 (Monitor negative output selection), there are f... More Details >>
- No:20938
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL
31-40 of Total 1368