FAQ within [ Drive Products ]
-
Difference between the current command and torque
The “current command” is the command value for the current control (torque control) and the “torque” is the feedback value controlled by the current control ... More Details >>
- No:23624
- Release Date:2018/09/14 15:10
- Category: MELSERVO-J4 , MELSERVO-JE , MELSERVO-JN , MELSERVO-J3 , MELSERVO Others
-
Parameter No.79 (Operation mode)
You cannot cancel multi-speed command input. When the multi-speed command is input from the terminal, you cannot use the potentiometer. Use the inverter so t... More Details >>
- No:21467
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-E500
-
Output side earth (ground) fault overcurrent protection
1. How much is the sensitivity current? When the sum of the three-phase output current of the inverter reaches approximately 70% of the inverter rated curren... More Details >>
- No:21394
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-A500 , FREQROL-A024 , FREQROL-E500
-
Set Pr.340 (Communication startup mode selection) to "1" or "2".Also, by setting Pr.79 (Operation mode selection) to "0", "2", or "6", the inverter enters th... More Details >>
- No:21879
- Release Date:2018/08/22 16:29
- Category: Inverters-FREQROL , FREQROL-E700 , FREQROL-A700 , FREQROL-F700 , FREQROL-F700P
-
Difference between SU (up to frequency) and FU (frequency detection)
- SU signal (up to frequency signal)This signal is output when the inverter output frequency reaches the set frequency (the frequency the inverter is require... More Details >>
- No:21436
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-E500
-
Parameter group is not displayed.
Some parameters are write-protected. (MR-J4/MR-J3: PA19)The parameter to be displayed is determined by the setting value of this parameter. Do as follows for... More Details >>
- No:23657
- Release Date:2018/09/14 15:10
- Category: MELSERVO-J3 , MELSERVO-J4
-
Using MR Configurator2, you can perform the positioning operation when there is no command from the controller. You can perform the operation specifying the ... More Details >>
- No:23640
- Release Date:2018/09/14 15:10
- Category: Servo Support Software , MELSERVO-J4 , MELSERVO-JE , MELSERVO-JN , MELSERVO-J3
-
Automatic restart after instantaneous power failure
1. Yes. The inverter cannot restart if STF and STR are turned OFF.However, on the next startup, the inverter detects coasting and restarts.2. When automatic ... More Details >>
- No:21942
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-V200
-
The FREQROL-A200 has magnetic flux vector control in addition to the conventional V/F control. Magnetic flux vector control controls the motor with higher ac... More Details >>
- No:21637
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , FREQROL-A200
-
We offer supports globally. Please make any inquiries to one of our FA centers attached to our local offices. More Details >>
- No:20782
- Release Date:2018/08/21 16:10
- Category: Geared Motors Parallel shaft type , Geared Motors Right angle shaft type , S-PM Geared Motors Parallel shaft type , S-PM Geared Motors Right angle shaft type