FAQ within [ Drive Products ]
-
Pr.59 is available in the products manufactured in October 1995 or later. Therefore, it cannot be read from the products manufactured before October 1995. More Details >>
- No:21170
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , FREQROL-A024
-
When the winding ratio is large, the control according to the winding diameter is required. The upper controller has measured the winding diameter and create... More Details >>
- No:20974
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , FREQROL-A800
-
From before, the QCPU has been used and each setting does not make a difference internally. Thus, the selection was reduced to the QCPU only. It can also be ... More Details >>
- No:20868
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , Engineering Software
-
Yes, they can. More Details >>
- No:20856
- Release Date:2018/08/22 16:24
- Category: FREQROL-A800
-
FR-A800 "Parameter for the communication setting"
These parameters are used for the communication compatible with the communication protocol of the Ethernet IP of the HMS optional circuit board (A8NEIP_2P). More Details >>
- No:20824
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , FREQROL-A800
-
If Pr.79 (Operation mode) is set to "0" (PU/EXT switching mode), press the PU/EXT button on the operation panel to turn on the PU LED.Turn the setting dial t... More Details >>
- No:21855
- Release Date:2018/08/22 16:29
- Category: Inverters-FREQROL , FREQROL-E700 , FREQROL-D700 , FREQROL-A700 , FREQROL-F700 , FREQROL-F700P , FREQROL-F700PJ
-
The parameters used when the terminal 4 is used are C5, C6, 126, and C7.Set Pr.C5 (Terminal 4 frequency setting bias frequency) while feeding a current signa... More Details >>
- No:21800
- Release Date:2018/08/22 16:29
- Category: Inverters-FREQROL , FREQROL-E700 , FREQROL-D700 , FREQROL-A700 , FREQROL-F700 , FREQROL-F700P , FREQROL-F700PJ
-
Is the forced stop signal wiring necessary?
For the safety of use, the wiring is recommended. If not using the wiring, set the parameter No. PA04 to “0100”. More Details >>
- No:23645
- Release Date:2018/09/14 15:10
- Category: MELSERVO-J4
-
I use the dedicated motor SF-VR with the same capacity as the inverter. 1. Load fluctuationSpeed fluctuation ratio with the load fluctuation 0 to 100% is:Wit... More Details >>
- No:21490
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-V200
-
It is available since November, 2007. The model is FR-A7ND E kit. More Details >>
- No:21321
- Release Date:2018/08/22 16:27
- Category: FREQROL-E700
391-400 of Total 1353