FAQ


FAQAbout Products
FAQ
Keyword Search
Drive Products
-
FREQROL-A800(144)
FREQROL-F800(89)
FREQROL-A700(352)
FREQROL-D700(261)
FREQROL-E700(394)
FREQROL-F700(296)
FREQROL-F700P(295)
FREQROL-F700PJ(252)
FREQROL-A024(40)
FREQROL-A100(21)
FREQROL-A200(32)
FREQROL-A500(123)
FREQROL-B(10)
FREQROL-E500(85)
FREQROL-F400(2)
FREQROL-F500(15)
FREQROL-S500(11)
FREQROL-U100(16)
FREQROL-V200(52)
FREQROL-Z020(1)
FREQROL-Z024(2)
FREQROL-Z100(2)
FREQROL-Z123(2)
FREQROL-Z200(3)
FREQROL-Z300(2)
SC-A(12)
Engineering Software(43)
Magnet motor drive(9)
Peripheral devices(7)
Options(129)
Plug-in Options(30)
Others(53)
FAQ within [ Drive Products ]
-
FR Configurator SW3 (CC-Link Seamless)
It cannot be opened because FR Configurator SW3 and FR Configurator SW3 (CC-Link Seamless) are not compatible. More Details >>
- No:21172
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , Engineering Software
-
It is one of other communication errors. The communication is not established. Check the communication settings. More Details >>
- No:21176
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , Engineering Software
-
It is available since November, 2007. The model is FR-A7ND E kit. More Details >>
- No:21321
- Release Date:2018/08/22 16:27
- Category: FREQROL-E700
-
Functions available when using inverter on CC-Link
You can use the regular terminal block wire functions during CC-Link operation. Set Pr.338 (Operation command source) and Pr.339 (Speed command source) to e... More Details >>
- No:21393
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-A500
-
Frequent occurrences of OL means that the inverter is overloaded. Since the inverter can go faulty if it is constantly overloaded, you need to take a counter... More Details >>
- No:21430
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-E500
-
Details of zero current detection
1. The inverter also monitors the output current during DC injection brake operation in addition to normal operation. Therefore, zero current detection also ... More Details >>
- No:21481
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-A024
-
Certificate for special tax reduction for first year facilities
The special tax reduction for first year facilities is the taxation system for promoting investment in the reform of the energy supply. The required certific... More Details >>
- No:21514
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , Others
-
This error is displayed when the inverter and operation panel FR-PU04 cannot communicate with each other correctly or the reset signal remains ON. Therefore,... More Details >>
- No:21546
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , FREQROL-A500
-
Sensitivity current of earth leakage circuit breaker
The rated sensitivity current of the earth leakage circuit breaker can be calculated using the following equation. If the result is 30 mA or less, the NV-FA ... More Details >>
- No:21547
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , Peripheral devices
-
A reference sine wave signal is generated inside the high power factor converter, and transistors are configured and PWM switching is performed in the conver... More Details >>
- No:21574
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , Options
411-420 of Total 1368