FAQ


FAQAbout Products
FAQ
Keyword Search
Drive Products
-
FREQROL-A800(144)
FREQROL-F800(89)
FREQROL-A700(352)
FREQROL-D700(261)
FREQROL-E700(394)
FREQROL-F700(296)
FREQROL-F700P(295)
FREQROL-F700PJ(252)
FREQROL-A024(40)
FREQROL-A100(21)
FREQROL-A200(32)
FREQROL-A500(123)
FREQROL-B(10)
FREQROL-E500(85)
FREQROL-F400(2)
FREQROL-F500(15)
FREQROL-S500(11)
FREQROL-U100(16)
FREQROL-V200(52)
FREQROL-Z020(1)
FREQROL-Z024(2)
FREQROL-Z100(2)
FREQROL-Z123(2)
FREQROL-Z200(3)
FREQROL-Z300(2)
SC-A(12)
Engineering Software(43)
Magnet motor drive(9)
Peripheral devices(7)
Options(129)
Plug-in Options(30)
Others(53)
FAQ within [ Drive Products ]
-
The resistor unit MT-BR5 manufactured in February 2016 or later has output terminal TH3 (NC contact) as a fault output terminal. More Details >>
- No:20816
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , Options
-
The response delay time is 10 ms normally and 100 ms at startup. More Details >>
- No:20821
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , Plug-in Options
-
It is possible when Pr.23 = 0 (Current limit at regenerative driving). More Details >>
- No:20826
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , Options
-
Perform the writing after turning ON the SOF, or after stopping the FR-HC2 by pressing the STOP button. Wire the RDY signal so that the inverter stops when t... More Details >>
- No:20842
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , Options
-
Yes, it does, however, it does not acquire the certification of the BACnet association standard. More Details >>
- No:20863
- Release Date:2018/08/22 16:24
- Category: FREQROL-F800
-
The FR-E7TR does not have the terminal for the SC and it cannot be used with the FR-E700-SC. More Details >>
- No:20865
- Release Date:2018/08/22 16:24
- Category: FREQROL-E700
-
When the value is written to Pr.646 (Stored winding diameter), the stored value is used. When the value is not written, the minimum or maximum winding diamet... More Details >>
- No:20887
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , FREQROL-A800
-
If Pr.361 = 0, the second terminal can be used as the line speed command when X114 is ON, and as the frequency setting value when X114 is OFF. If Pr.361 = 3,... More Details >>
- No:20891
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , FREQROL-A800
-
The tension PI gain can be adjusted automatically by performing the tension PI gain tuning. More Details >>
- No:20923
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , FREQROL-A800
-
For output signals, up to 10 points (RXn2 to RXB) can be assigned. It is possible if the number of the importing signal points are within this range. More Details >>
- No:20943
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , Plug-in Options
441-450 of Total 1368