FAQ within [ Drive Products ]
-
Refer to the inverter capacity. More Details >>
- No:21200
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
There is no regulation value. Use the inverters in the environment without corrosive gas. More Details >>
- No:21201
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
It is approximately 500,000 times in the rated specification. More Details >>
- No:21202
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
When the brake sequence function is enabled, the RT signal is disabled and the stop-on-contact control cannot be performed. More Details >>
- No:21209
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
LED blinking under encoder feedback control
The following may be the cause. - No encoder power supply. - The setting of Pr.359 (Encoder rotation direction) is reversed. - The signal from the encoder is... More Details >>
- No:21219
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
Remote input signal of CC-Link communication
When the communication error occurs, the input signal status is not retained, and all the bits turn OFF. When the communication establishes again, the bit tu... More Details >>
- No:21237
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
They are insulated. More Details >>
- No:21242
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
Check that the correct rated motor current is set in Pr.9 (Electronic thermal O/L relay). No parameter is available for setting the operation time of the ele... More Details >>
- No:21291
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , FREQROL-E700 , FREQROL-D700 , FREQROL-A700 , FREQROL-F700PJ
-
Advanced magnetic flux vector control
It can be used with the FR-A700 and FR-E700 series. More Details >>
- No:21298
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , FREQROL-E700 , FREQROL-A700
-
Vector control of the inverter
The speed fluctuation ratio under Advanced magnetic flux vector control of the FR-A500 is as follows. Without encoder: ±1% With encoder (with A5AP): ±0. 02 %... More Details >>
- No:21369
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-A500