FAQ


FAQAbout Products
FAQ
Keyword Search
Drive Products
-
FREQROL-A800(142)
FREQROL-F800(89)
FREQROL-A700(351)
FREQROL-D700(260)
FREQROL-E700(393)
FREQROL-F700(295)
FREQROL-F700P(294)
FREQROL-F700PJ(251)
FREQROL-A024(40)
FREQROL-A100(21)
FREQROL-A200(32)
FREQROL-A500(119)
FREQROL-B(9)
FREQROL-E500(84)
FREQROL-F400(2)
FREQROL-F500(15)
FREQROL-S500(11)
FREQROL-U100(16)
FREQROL-V200(51)
FREQROL-Z020(1)
FREQROL-Z024(2)
FREQROL-Z100(2)
FREQROL-Z123(2)
FREQROL-Z200(3)
FREQROL-Z300(2)
SC-A(12)
Engineering Software(41)
Magnet motor drive(9)
Peripheral devices(7)
Options(127)
Plug-in Options(30)
Others(53)
FAQ within [ Drive Products ]
-
Only the parameter setting values (USB memory parameter copy file: CP1 file) read from the inverter to USB memory can be edited. Customers cannot generate a ... More Details >>
- No:21007
- Release Date:2018/08/22 16:25
- Category: Engineering Software
-
Both settings of Pr.83 and Pr.84 are enabled immediately. However, the output voltage is not changed because the value of Pr.83 has little influence on Vecto... More Details >>
- No:21022
- Release Date:2018/08/22 16:25
- Category: FREQROL-A800
-
A separate power supply is required according to the encoder power supply specification. More Details >>
- No:21090
- Release Date:2018/08/22 16:25
- Category: FREQROL-A800
-
PDF data is available free of charge with free registration from the Mitsubishi Electric FA Global Website. All the printed materials are available for a fee. More Details >>
- No:21127
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , Others
-
The corresponding bit (RYB) can be used when a function other than reset is assigned to the RES terminal, but it cannot be used as the reset function. Use RY... More Details >>
- No:21142
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , Plug-in Options
-
The power of MC1 is supplied from the terminals across R2 and S2 of the outside box. Either phase of R2 or S2 may be lost. More Details >>
- No:21146
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , Options
-
Indication of potentiometer on operation panel
The potentiometer on the operation panel is initially calibrated so that the maximum indication is slightly over 60 Hz with the potentiometer turned to the m... More Details >>
- No:21427
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-E500
-
The FR-B type 30K or higher products have passed the explosion-proof test certified by the Ministry of Health, Labour and Welfare with the maximum frequency ... More Details >>
- No:21488
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-B
-
Refer to the outline dimension. More Details >>
- No:21513
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , FREQROL-E500
-
If all inverters are in regenerative operation, the regenerative power is regenerated to the power supply. If one of the inverters is power driving, the rege... More Details >>
- No:21564
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , Options
481-490 of Total 1353