FAQ within [ Drive Products ]
-
All FR-CC2 support the coating as standard. More Details >>
- No:20916
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL
-
It is the length from the support of the rope to the center of gravity of the swinging. More Details >>
- No:20934
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL
-
An earth plate permanently installed in the 700 series is included as an option for the 800 series because of the change of the shape of the circuit board. More Details >>
- No:21035
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL
-
Data with different capacity can be imported. Data with different voltage or model cannot be imported. More Details >>
- No:21196
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
Watt-hour meter clear and operation hour meter clear
The values are set to Pr.170 and 171 when the monitor value of cumulative power and actual operation time overflows. It does not affect the operation. Use it... More Details >>
- No:21197
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
There is no setting to disable it, but setting a high torque limit level such as 400 % can disable the limit. More Details >>
- No:21217
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
Monitor value at CC-Link communication
The data of output frequency, output current, and output voltage are retained at alarm occurrence, but other monitors are not. More Details >>
- No:21235
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
Issues of driving the wound rotor motor inverter
The wound rotor motor can be used in the same way as cage-induction motors by shortening the resistor at the secondary side. More Details >>
- No:21370
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL
-
Is the number of writing times of the parameter memory limited?
1. The limit of the parameter writing is 100,000 times. 2. Parameter error occurs. Since the data in the ROM may be broken, the inverter may become unavailab... More Details >>
- No:21385
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-A500
-
Wire length between inverter and motor
1. Wiring length between the inverter and the motor should be 500 m or less. For 0.75 kW or lower motors, the following relationship is true: Capacity... More Details >>
- No:21392
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL