FAQ within [ Drive Products ]
-
Impossible to recover after power failure
First, ensure that the parameter for automatic restart after instantaneous power failure is set correctly and then do the following:1. Check if the terminals... More Details >>
- No:22033
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-A500
-
The inverter does not have a function to limit the current at 0 Hz.Although it has the DC injection brake, it is intended to improve the braking capability b... More Details >>
- No:22002
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-A500
-
Before you change Pr.7 and Pr.8, you must switch to the PU operation mode. Switch to the PU operation mode and change them. More Details >>
- No:21984
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-F500
-
Speed adjustment of multiple inverters using variable resistor
You can connect up to three inverters in parallel to an external variable resistor. Refer to the figure below for a connection example. By setting parameters... More Details >>
- No:21980
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
The rotation ripple data for 1.5 kW is shown below.Drive unit: MD-CX520-1.5KMotor: MM-CF152Load: None (motor alone), carrier frequency: 2 kHz, wiring length:... More Details >>
- No:21968
- Release Date:2018/08/22 16:30
- Category: Magnet motor drive
-
Take the following countermeasure:1. If the thermal trips in low-speed operation, trips can be avoided, depending on the external thermal relay operation cha... More Details >>
- No:21954
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-E500
-
Change Pr.18 (High speed maximum frequency) to 400 Hz.If you are using the analog command to set the frequency, calibrate the 400 Hz frequency with Pr.903. More Details >>
- No:21931
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-A500
-
Operation at base frequency or higher
The output frequency is 55 Hz. (For V/F control)When the base frequency is set to 50 Hz, frequencies over 50 Hz is the constant output range.Note that the ma... More Details >>
- No:21923
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
Set Pr.340 (Communication startup mode selection) to other than "0".Also, set Pr.79 (Operation mode) to "0", "2", or "6".Powering the inverter on automatical... More Details >>
- No:21903
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-E700 , FREQROL-A700 , FREQROL-F700 , FREQROL-F700P
-
Yes, but the optional kit (FR-A7NC E kit) is necessary. More Details >>
- No:21877
- Release Date:2018/08/22 16:29
- Category: FREQROL-E700