FAQ within [ Drive Products ]
-
You can use the Hioki Memory HiCorder and clamp-on AC/DC high tester.You can observe the inverter's frequency in one of the following two methods:1. Attach t... More Details >>
- No:22082
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-A500 , FREQROL-E500
-
Set Pr.340 (Communication startup mode selection) to other than "0".Also, set Pr.79 (Operation mode) to "0", "2", or "6".Powering the inverter on automatical... More Details >>
- No:21903
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-E700 , FREQROL-A700 , FREQROL-F700 , FREQROL-F700P
-
It is OK if stations are set as reserved. More Details >>
- No:21868
- Release Date:2018/08/22 16:29
- Category: Inverters-FREQROL , FREQROL-E700 , FREQROL-A700 , FREQROL-F700 , FREQROL-F700P
-
When running the inverter in Advanced magnetic flux vector control, the frequency setting value is increased by the amount of the motor's slippage, resulting... More Details >>
- No:21801
- Release Date:2018/08/22 16:29
- Category: Inverters-FREQROL , FREQROL-E700 , FREQROL-A700
-
Advanced magnetic flux vector control
When using the geared motor GM-S(B), set Pr.71 to "13" and also set Pr.9, Pr.80, and Pr.81.Perform auto tuning as required. Perform auto tuning as required. ... More Details >>
- No:21756
- Release Date:2018/08/22 16:29
- Category: Inverters-FREQROL , FREQROL-E700 , FREQROL-A700
-
Set Pr.270 (Stop-on-contact control) to "1".Set Pr.184 (RES terminal function selection) to "3" to choose the RT signal function.When the terminals RL and RT... More Details >>
- No:21691
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , FREQROL-E700 , FREQROL-A700
-
Can I change the carrier frequency?
You can change it by changing the setting of Pr.72 (PWM frequency selection). Setting range of Pr.72: 0, 1, 2, 3, 4, 5, 6 (Initial setting is "6".) (The smal... More Details >>
- No:21640
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , FREQROL-V200
-
You can remove the parameter unit FR-PU02 and install the FR-CU01 there. However, since the interface for the parameter unit is used, the communication speed... More Details >>
- No:21625
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , Others , FREQROL-A200
-
Countermeasure against noise and leakage current during low-noise operation
The following two major countermeasures against noise are available: - Keep the noise source and partner device apart from each other.- Install a noise filte... More Details >>
- No:21605
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , FREQROL-A024
-
Connection with personal computer
Connection method for the A500 and E500 is shown in the figure below. The figure is given in an Excel file. Figure 1 More Details >>
- No:21536
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , FREQROL-A500 , FREQROL-E500