FAQ


FAQAbout Products

FAQ
Keyword Search
Drive Products
-
FREQROL-A800(144)
FREQROL-F800(89)
FREQROL-A700(352)
FREQROL-D700(261)
FREQROL-E700(394)
FREQROL-F700(296)
FREQROL-F700P(295)
FREQROL-F700PJ(252)
FREQROL-A024(40)
FREQROL-A100(21)
FREQROL-A200(32)
FREQROL-A500(123)
FREQROL-B(10)
FREQROL-E500(85)
FREQROL-F400(2)
FREQROL-F500(15)
FREQROL-S500(11)
FREQROL-U100(16)
FREQROL-V200(52)
FREQROL-Z020(1)
FREQROL-Z024(2)
FREQROL-Z100(2)
FREQROL-Z123(2)
FREQROL-Z200(3)
FREQROL-Z300(2)
SC-A(12)
Engineering Software(43)
Magnet motor drive(9)
Peripheral devices(7)
Options(129)
Plug-in Options(30)
Others(53)
FAQ within [ Drive Products ]
-
Since the terminal FM is designed with 8 V peak pulse voltage output, it cannot output 10 V.Since the terminal AM is an analog output of 0 V to 10 V, use thi... More Details >>
- No:21978
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-A500
-
Pr.133 can be written.Since the data code numbers of parameters are duplicate, target parameters are switched by link parameter extended setting.You can acce... More Details >>
- No:21976
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , Plug-in Options , FREQROL-A500 , FREQROL-F500
-
External wiring for CC-Link operation
For the combination of the FR-A500 + FR-A5NC, Pr.338 and Pr.339 are used to specify whether the external signals or CC-Link commands are used to set the runn... More Details >>
- No:21973
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-A500 , FREQROL-E500
-
Inverter 200 V input and 400 V output
We do not have an inverter that directly takes 200 V input and generates 440 V output. Therefore, as you mention, use a 400 V class inverter by boosting the ... More Details >>
- No:21971
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
EMC compliant filter terminal cover
The SF1258 has the terminal cover.Although the SF1259 to SF1263 do not have the terminal covers and their terminals are bare, rubber tubes to cover them are ... More Details >>
- No:21956
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , Options
-
Short-circuiting frequency setting terminals
You can short-circuit the terminals 10 and 2.If you are considering to perform operation at the maximum frequency, consider using the high-speed command RH o... More Details >>
- No:21951
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
Operation of automatic restart after instantaneous power failure
1. No operation log is recorded.2. No. However, you can create a state indicating that automatic restart after instantaneous power failure is in progress by ... More Details >>
- No:21948
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-A500
-
1. The BU brake unit does not have the fault output.Multiple BU brake units can be connected in parallel.2. Power supply voltage 480 V- What resistance value... More Details >>
- No:21930
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , Options
-
1. No parameter setting is required.2. Do not remove the jumpers. More Details >>
- No:21927
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , Options
-
You can do so by assigning the terminal AU.Assign the terminal AU to an unused terminal.(For example, when assigning AU to the terminal RL, set Pr.180 = 4.)B... More Details >>
- No:21915
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-E700 , FREQROL-D700 , FREQROL-A700 , FREQROL-F700 , FREQROL-F700P , FREQROL-F700PJ
561-570 of Total 1368