FAQ within [ Drive Products ]
-
Reverse operation is enabled by changing the setting of Pr.40. More Details >>
- No:21287
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , FREQROL-E700 , FREQROL-D700 , FREQROL-F700PJ
-
It can be driven by connecting single-phase 200 V to the terminals R and S. In this case, the load current must be one-third or less of the inverter rated cu... More Details >>
- No:21282
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , FREQROL-E700
-
When Pr.80 and Pr.81 are set to the value other than "9999", control other than V/F control is performed. For the FR-F700(P) FR-D700, and FR-F700PJ, Pr.81 is... More Details >>
- No:21259
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , FREQROL-E700 , FREQROL-D700 , FREQROL-A700 , FREQROL-F700 , FREQROL-F700P , FREQROL-F700PJ
-
It is Pr.125 (Terminal 2 frequency setting gain frequency). Adjust the slope with C4 (903) (Terminal 2 frequency setting gain) as necessary. More Details >>
- No:21247
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , FREQROL-E700 , FREQROL-D700 , FREQROL-A700 , FREQROL-F700 , FREQROL-F700P , FREQROL-F700PJ
-
Wiring of CC-Link communication cable
The communication is established if DA, DB, and DG are connected each other. More Details >>
- No:21239
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
It is approximately 500,000 times in the rated specification. More Details >>
- No:21202
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
FR Configurator SW3 (CC-Link Seamless)
Pr.77 and 79 cannot be changed via CC-Link communication. More Details >>
- No:21174
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , Engineering Software
-
FR Configurator SW3 (CC-Link Seamless)
It cannot be opened because FR Configurator SW3 and FR Configurator SW3 (CC-Link Seamless) are not compatible. More Details >>
- No:21172
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , Engineering Software
-
Save the parameter file (.rpm) after reading the system file (.mel) created in SW1. With the saved parameter file (.rpm), the parameter of the 700 series can... More Details >>
- No:21141
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , Engineering Software
-
Under Real sensorless vector control, the maximum wiring length is 500 m. Under Vector control with encoder, the maximum wiring length is 100 m. More Details >>
- No:21133
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , FREQROL-A700