FAQ within [ Drive Products ]
-
When the second torque limit is used, the settings of Pr.816 and 817 are valid. More Details >>
- No:21218
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
System environment variable of the Modbus-RTU communication
Other than "0" can be input. The inverter is reset by writing any numerical value. More Details >>
- No:21224
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
It is tilted to wire the cable easily. More Details >>
- No:21228
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
Remote input signal of CC-Link communication
When the communication error occurs, the input signal status is not retained, and all the bits turn OFF. When the communication establishes again, the bit tu... More Details >>
- No:21237
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
Common connection of the terminal SD
There is no problem for only the terminal SD connection because undesirable current will not be flown. More Details >>
- No:21379
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL
-
When measuring current, if you open the output side while current is flowing on the input side, high voltage is induced and dielectric breakdown may occur wi... More Details >>
- No:21399
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL
-
Can I use a motor of which capacity is larger than the inverter capacity?
Even when the actual load (torque) is half of the motor capacity, the current output from the inverter to the motor is not reduced to the half. Therefore, it... More Details >>
- No:21442
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL
-
"PS" appears when the STOP key on the operation panel is pressed during external operation. It is considered that someone pressed the key. Dismiss "PS" in on... More Details >>
- No:21478
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-E500
-
Inverter 200 V input and 400 V output
We do not have an inverter that directly takes 200 V input and generates 440 V output. Therefore, as you mention, use a 400 V class inverter by boosting the ... More Details >>
- No:21971
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
PHS does not cause the inverter to malfunction.On the contrary, if you use PHS near an inverter or motor, communication over PHS may become noisy or even get... More Details >>
- No:22018
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL