FAQ within [ Drive Products ]
-
The deceleration stop is also performed according to the setting in Pr.815 under V/F control. More Details >>
- No:20957
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , FREQROL-A800
-
The country in which the product is manufactured is described on the rating plate as MADE IN JAPAN or MADE IN CHINA. More Details >>
- No:20956
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , FREQROL-A800 , FREQROL-F800
-
Carrier frequency automatic reducing function
The function operates immediately when the current of 85% or higher flows. The limit is canceled when the current becomes 80% or lower. More Details >>
- No:20903
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , FREQROL-A800 , FREQROL-F800
-
There are some restrictions compared to the FR-A800 (RS-485 communication type). For example, the FR-A8TR is unavailable, and only two option connectors are ... More Details >>
- No:20884
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , FREQROL-A800 , FREQROL-F800
-
Up to 64 (slave stations). The number of connectable units differs depending on the master station. More Details >>
- No:20857
- Release Date:2018/08/22 16:24
- Category: FREQROL-A800 , FREQROL-F800
-
Two digits after the decimal point are rounded off. 28.139 Hz is rounded down to 28.13 Hz. More Details >>
- No:20812
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , Plug-in Options
-
Is the forced stop signal wiring necessary?
For the safety of use, the wiring is recommended. If not using the wiring, set the parameter No. PA04 to “0100”. More Details >>
- No:23645
- Release Date:2018/09/14 15:10
- Category: MELSERVO-J4
-
Switching from star-delta operation
It is probable that the torque is insufficient because the load characteristics and inverter output characteristics do not match and the output current value... More Details >>
- No:22049
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
The following benefits are provided when the FR-BLF is installed on the input side or output side.Choose the side to install the FR-BLF considering these ben... More Details >>
- No:22026
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , Options
-
Speed 2 operation with potentiometer on operation panel
Yes. Set parameters as below.For FR-E500Set Pr.79 =3, and Pr.146= 0.Multi-speed is prioritized.For FR-S500Set Pr.79 = 3, and Pr.53 = 1.Multi-speed is priorit... More Details >>
- No:21963
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-E500 , FREQROL-S500