FAQ within [ Drive Products ]
-
Refer to the following points.For fan pump -> Square torqueFor general-purpose machine (for example, transport, elevation) -> Constant-torque type More Details >>
- No:22048
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-A500
-
The specifications of the FR-V200E series do not allow for choosing from "Reset input always enabled" and "Reset input enabled only when the protective funct... More Details >>
- No:22031
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-V200
-
Changing main speed at analog signal input
To change the running frequency while the frequency command is input to the terminal 2, adjust the parameters in the following steps:1. Change Pr.77 to "2".2... More Details >>
- No:22025
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-A500
-
How can I have the motor coast to stop?
You can use the following two methods:1. Turn ON MRS at the same time when STF turns OFF.2. Set Pr.10 = 60 Hz, Pr.11 = 0 sec, and Pr.12 = 0% (when the invert... More Details >>
- No:21967
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
Automatic restart after instantaneous power failure
1. Yes. The inverter cannot restart if STF and STR are turned OFF.However, on the next startup, the inverter detects coasting and restarts.2. When automatic ... More Details >>
- No:21942
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-V200
-
Check if any device is connected to the inverter's external terminal.In particular, check if MRS and SD are short-circuited.If they are short-circuited, open... More Details >>
- No:21753
- Release Date:2018/08/22 16:29
- Category: Inverters-FREQROL , FREQROL-E700 , FREQROL-A700
-
Installing contactor on input side
It is not recommended to install a contactor on the input side and connect the auxiliary contact to the terminal STF of the inverter for the following reason... More Details >>
- No:21533
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL
-
Countermeasure against harmonics
Perform calculation given in the harmonic suppression guidelines, and if the limit value is exceeded, you may also need to insert the ACL. Note that you cann... More Details >>
- No:21465
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , Options
-
The inverter alarm "OV3" occurs when the main circuit DC voltage inside the inverter goes higher than the preset value due to the regenerative power returned... More Details >>
- No:21438
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-A024
-
Resetting inverter after restoring from power failure
When the programmable controller power is turned OFF while the inverter is in the PLC link operation mode, a communication error occurs and the inverter trip... More Details >>
- No:21417
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , Plug-in Options , FREQROL-A500