FAQ within [ Drive Products ]
-
What is the replacement of the FR-BOL?
We do not offer a replacement product for the FR-BOL (noise reduction reactor). Since the FR-A100E is a low-noise type inverter, the motor noise is suppresse... More Details >>
- No:21500
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , Options
-
Motor heat generation at low-speed operation
When using the FR-A540-3.7K in Advanced magnetic flux vector control, operating the motor continuously under the 100% torque at up to 3 Hz does not cause a h... More Details >>
- No:21496
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-A500
-
Connect the external potentiometer to the terminals 10, 2, and 5 of the first inverter (be sure to connect the variable terminal to the terminal 2). Connect ... More Details >>
- No:21462
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-V200
-
The FR-A500 series that is the successor of the FR-A200E series has a function similar to output current detection of the FR-E500. Consider using the FR-A500... More Details >>
- No:21453
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-A500 , FREQROL-A200
-
Relationship between frequency and load current
If the load is heavy and the output current is higher than the control value, you can adjust Pr.22 (Stall prevention operation level) to trigger the stall pr... More Details >>
- No:21450
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL
-
Yes. "OL" is displayed under speed control whenever the torque limit is reached without regard to the rated torque. More Details >>
- No:21448
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-V200
-
There is a 10 ms delay after the inverter recognizes the start command (STF OR STR) before it starts decelerating. The delay is 10 ms. A delay of 100 ms is i... More Details >>
- No:21445
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-A500
-
12-bit digital input and others
You can switch between PU operation and external operation using the plug-in option "12-bit digital input" card and external contact signals. After setting P... More Details >>
- No:21432
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-A500 , FREQROL-A200
-
Unwinding using vector inverter
1. Torque control automatically adjust the speed so that the instructed torque value is maintained. This means that the speed is not controlled. (However, yo... More Details >>
- No:21420
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-V200
-
To conform to the EMC Directive when exporting to an EU country, install the filter that conforms to the EMC Directive on the inverter, and take measures acc... More Details >>
- No:21414
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-A500