FAQ within [ Drive Products ]
-
Electronic thermal O/L relay setting
Set Pr.9 to the rated current at 50 Hz or a value 1.1 times as the rated current at 60 Hz.You can specify the motor type with Pr.71 (Applied motor). For a co... More Details >>
- No:21941
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
Driving two motors with different capacities
It is OK to drive motors by switching the electromagnetic contactor on the inverter's output side.It is also OK if the motor capacity is small. However, if t... More Details >>
- No:22022
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-A500
-
The power factor is 0.99 or more (at rated load). More Details >>
- No:20803
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , Options
-
Yes, it can. More Details >>
- No:20806
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , Options , FREQROL-A800
-
It is for the HIV cable. More Details >>
- No:20850
- Release Date:2018/08/22 16:24
- Category: Options
-
Yes. More Details >>
- No:20986
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , Options
-
Remote operation of the inverter
The wiring length of the start signal (STF etc.) is 30 m or less. The circuit voltage of the control input signals (terminal STF etc.) is 24 VDC and the volt... More Details >>
- No:21380
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-A500
-
Countermeasures when input power supply is turned off upon equipment fault
1. When the inverter power supply is turned OFF, the inverter is disconnected from the CC-Link network. However, since the CC-Link master station has the aut... More Details >>
- No:21390
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-A500 , FREQROL-E500
-
We recommend the "YM206RI 1 mA" analog ammeter. More Details >>
- No:21402
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , Options
-
Load current limit of inverter
You can input current from the terminal AM of the inverter to the programmable controller (for A/D conversion) and control the speed with the software of the... More Details >>
- No:21419
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-A500