FAQ within [ Drive Products ]
-
Communication operation with FR-E500
We have no sample program for RS485 communication. Since the communication method of the FR-SW0-SETUP uses a different protocol from 485 communication and st... More Details >>
- No:21451
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-E500
-
Ensure that the inverter is in the PU operation mode and stopped, change the following parameters: 1. Read Pr.923 (Built-in frequency setting potentiometer g... More Details >>
- No:21416
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-E500
-
To conform to the EMC Directive when exporting to an EU country, install the filter that conforms to the EMC Directive on the inverter, and take measures acc... More Details >>
- No:21414
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-A500
-
Priority of multi-speed setting and frequency setting signals
For frequency setting, multi-speed setting is prioritized over current input. Therefore, when the multi-speed signal is input, the inverter switch to multi-s... More Details >>
- No:21400
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL
-
The stop-on-contact control does not function in the combined operation mode. Perform the control in the External operation mode. More Details >>
- No:21354
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-E700 , FREQROL-A700
-
Use high-duty brake resistor FR-ABR-2.2K. (Shared with the 1.5K inverter.) More Details >>
- No:21330
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-E700 , FREQROL-D700 , FREQROL-A700 , FREQROL-F700 , FREQROL-F700P , FREQROL-F700PJ
-
Yes. The model is FR-E710W. The input is single-phase 100 V, but the output is three-phase 200 V. More Details >>
- No:21320
- Release Date:2018/08/22 16:27
- Category: FREQROL-E700
-
Supported model for FR-Configurator
For the models other than FR-A700/F700, use FR-Configurator (FR-SW3-SETUP-WJ). They are not supported by FR-Configurator (FR-SW2-SETUP-WJ). When you have the... More Details >>
- No:21313
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , FREQROL-E700 , FREQROL-D700 , FREQROL-A700 , FREQROL-F700 , FREQROL-F700P , FREQROL-F700PJ
-
When the built-in brake resistor is used, the regenerative brake duty is as follows:200 V 0.4K to 3.7K: 3%, 5.5K to 7.5K: 2%400 V 0.4K to 7.5K: 2 % The capac... More Details >>
- No:21273
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , FREQROL-A700
-
The corresponding bit (RYB) can be used when a function other than reset is assigned to the RES terminal, but it cannot be used as the reset function. Use RY... More Details >>
- No:21142
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , Plug-in Options