FAQ within [ Drive Products ]
-
"8" display in offline auto tuning means forced stop by the operator. This means that you stopped operation before tuning completes. With this forced stop, ... More Details >>
- No:21527
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , FREQROL-A500
-
Regenerative driving capability
Continuous 100% regenerative braking torque is available for the rated capacity of the high power factor converter. (The same braking ability of the FR-A201 ... More Details >>
- No:21563
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , Options
-
What parameters (settings) are available?
The following three functions can be set: - Acceleration/deceleration time- Electronic thermal O/L relay- Maximum frequencyThe parameter unit is not used but... More Details >>
- No:21584
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , SC-A
-
The FR-E720S series and D720S series conform to the single-phase 200 V input specifications. More Details >>
- No:21723
- Release Date:2018/08/22 16:29
- Category: Inverters-FREQROL , FREQROL-E700 , FREQROL-D700
-
When offline auto tuning ends normally, the setting of this parameter changes to "3".This means that auto tuning completed normally.If the setting value is "... More Details >>
- No:21748
- Release Date:2018/08/22 16:29
- Category: Inverters-FREQROL , FREQROL-E700 , FREQROL-A700
-
Current input switching operation
With your setting, since Pr.60 assigns the OH function to the terminal PL, and terminals RL and SD are open, an external protection error occurs. (It does no... More Details >>
- No:21975
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-S500
-
The surface temperature of approximately 70?C is OK.The following shows the MM-CF352 frame temperature for reference.(Actual temperature rise depends on how ... More Details >>
- No:21988
- Release Date:2018/08/22 16:30
- Category: Magnet motor drive
-
Control wire of FR-HC RDY signal
The contact between the terminals RDY and SE is open collector output.Operation is:Normal: Non-conductiveFault: Conductive More Details >>
- No:22017
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , Options
-
The operation panel of the FR-S500 is not detachable.For the FR-S500-○○K-R (compatible with RS-485 communication), you can install the FR-PU04 on the enclosu... More Details >>
- No:22058
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-S500
-
SW1DND-FRC2 (FR Configurator2)
SW1 is not supported because there is no product However, SW2 can be upgraded by entering the product ID. More Details >>
- No:21067
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , Engineering Software