FAQ within [ Drive Products ]
-
It is possible by using the terminal A to C with the negative logic setting. More Details >>
- No:21203
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
Because the multi-speed terminal is disabled, it does not operate in multi-speed. More Details >>
- No:21205
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
It is fixed to 5 kHz. More Details >>
- No:21211
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
There is no setting to disable it, but setting a high torque limit level such as 400 % can disable the limit. More Details >>
- No:21217
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
Inverter installation when using the FR-A7NCE
Normally, the required space for A700 3.7K or lower is 1 cm. However, when using CC-Link IE, it needs to be separated for 5 cm or more to pass the cable. More Details >>
- No:21227
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
Remote input signal of CC-Link communication
When the communication error occurs, the input signal status is not retained, and all the bits turn OFF. When the communication establishes again, the bit tu... More Details >>
- No:21237
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
Pr.268 (Monitor decimal digits selection) during CC-Link communication
No, it is not changed. Pr.268 is the parameter for the operation panel. More Details >>
- No:21241
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
The current value can be displayed on the operation panel without regard to the setting of monitor-related parameters. As the current value remains 0 A, the ... More Details >>
- No:21405
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL
-
Shielded wiring of external speed setting potentiometer
Grounding can often get dirty due to influence from the inverter main circuit switching. Therefore, when the potentiometer shielded wire is connected to the ... More Details >>
- No:21455
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL
-
Connecting voltmeter to terminal AM
You can connect them in parallel. Connect the voltmeters in parallel, paying attention to the following: - The output current should not exceed the permissib... More Details >>
- No:21464
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL
61-70 of Total 1368