FAQ


FAQAbout Products
FAQ
Keyword Search
Drive Products
-
FREQROL-A800(142)
FREQROL-F800(89)
FREQROL-A700(351)
FREQROL-D700(260)
FREQROL-E700(393)
FREQROL-F700(295)
FREQROL-F700P(294)
FREQROL-F700PJ(251)
FREQROL-A024(40)
FREQROL-A100(21)
FREQROL-A200(32)
FREQROL-A500(119)
FREQROL-B(9)
FREQROL-E500(84)
FREQROL-F400(2)
FREQROL-F500(15)
FREQROL-S500(11)
FREQROL-U100(16)
FREQROL-V200(51)
FREQROL-Z020(1)
FREQROL-Z024(2)
FREQROL-Z100(2)
FREQROL-Z123(2)
FREQROL-Z200(3)
FREQROL-Z300(2)
SC-A(12)
Engineering Software(41)
Magnet motor drive(9)
Peripheral devices(7)
Options(127)
Plug-in Options(30)
Others(53)
FAQ within [ Drive Products ]
-
Europe EMC Directive compliance
By turning ON the connector of the built-in filter, the inverter can be compliant with EMC Directive (EN 61800-3 2nd Environment C3) alone. More Details >>
- No:21116
- Release Date:2018/08/22 16:26
- Category: FREQROL-A800 , FREQROL-F800
-
Check that the correct rated motor current is set in Pr.9 (Electronic thermal O/L relay). No parameter is available for setting the operation time of the ele... More Details >>
- No:21291
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , FREQROL-E700 , FREQROL-D700 , FREQROL-A700 , FREQROL-F700PJ
-
Advanced magnetic flux vector control and General-purpose magnetic flux vector control
Advanced magnetic flux vector control provides a larger torque at low-speed. 3.7K or lower: 0.5 Hz/200%5.5K to 15K: 0.5 Hz/150% More Details >>
- No:21297
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , FREQROL-E700
-
The stop-on-contact control does not function in the combined operation mode. Perform the control in the External operation mode. More Details >>
- No:21354
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-E700 , FREQROL-A700
-
Encoder feedback speed accuracy
The speed variation rate is as follows: - Encoder feedback control: ±0.2% - Vector control: ±0.02% (mentioned in FR-A5AP Instruction Manual) More Details >>
- No:21422
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , Plug-in Options , FREQROL-A500
-
It is considered that communication settings between the inverter and personal computer do not match. Check if settings such as communication rate and stop b... More Details >>
- No:21431
- Release Date:2018/08/22 16:27
- Category: Engineering Software
-
Acquisition of pressure-resistant explosion-proof certification
The test institutes assigned by the Minister of Health, Labour and Welfare (National Institute of Occupational Safety and Health and Technology Institution o... More Details >>
- No:21510
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , Others , FREQROL-B
-
Installation dimensions of the heat sink panel through attachment
The heat sink panel through attachment to the FR-A520-5.5K inverter consist of the top installation frame, bottom installation frame, and upper cover. The to... More Details >>
- No:21520
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , Others , FREQROL-A500
-
Term definition and advanced magnetic flux control
1. Maximum torque available for output from the motor when combined with an inverter for a short period of time (1 minute or less). It depends on the contr... More Details >>
- No:21541
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , FREQROL-A500
-
Sensitivity current of earth leakage circuit breaker
The rated sensitivity current of the earth leakage circuit breaker can be calculated using the following equation. If the result is 30 mA or less, the NV-FA ... More Details >>
- No:21547
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , Peripheral devices
701-710 of Total 1353