FAQ within [ Drive Products ]
-
We offer DC reactors from 0.4K and you can use it. You can use FR-BIF, FR-BSF, and FR-BEL together. More Details >>
- No:21461
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , Options
-
Inverter with one-rank higher capacity
An inverter with one-rank higher capacity is often used when a high torque is required for a short period of time. (Examples)- When rapid acceleration/decele... More Details >>
- No:21456
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL
-
It is considered that conditions including the power supply and noise change whether the parameter unit is connected or disconnected, influencing the analog ... More Details >>
- No:21454
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-V200
-
Relationship between frequency and load current
If the load is heavy and the output current is higher than the control value, you can adjust Pr.22 (Stall prevention operation level) to trigger the stall pr... More Details >>
- No:21450
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL
-
From Z100 to A520: Use the FR-AAT01 to replace the Z100 with the A520. From Z100 to E520: No attachment is available since E520 is a new series. From Z100 to... More Details >>
- No:21447
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , Options , FREQROL-Z100
-
There is a 10 ms delay after the inverter recognizes the start command (STF OR STR) before it starts decelerating. The delay is 10 ms. A delay of 100 ms is i... More Details >>
- No:21445
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-A500
-
Can I use a motor of which capacity is larger than the inverter capacity?
Even when the actual load (torque) is half of the motor capacity, the current output from the inverter to the motor is not reduced to the half. Therefore, it... More Details >>
- No:21442
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL
-
The inverter alarm "OV3" occurs when the main circuit DC voltage inside the inverter goes higher than the preset value due to the regenerative power returned... More Details >>
- No:21438
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-A024
-
12-bit digital input and others
You can switch between PU operation and external operation using the plug-in option "12-bit digital input" card and external contact signals. After setting P... More Details >>
- No:21432
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-A500 , FREQROL-A200
-
It is considered that communication settings between the inverter and personal computer do not match. Check if settings such as communication rate and stop b... More Details >>
- No:21431
- Release Date:2018/08/22 16:27
- Category: Engineering Software