You can vary the carrier frequency within the range of 0.7 to 14.5 kHz, and it is initially set to 1 kHz that generates low noise and leakage current. You ca... More Details >>
- No:21607
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , FREQROL-A024
-
Compatibility of the function with FR-A100
Yes. Compared with the FR-A100:- The PI control function is added.- Fast-response current limit operation is improved.- Cumulative energy monitor is added. More Details >>
- No:21628
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , FREQROL-A100
-
Basically it is not possible due to the operation command source.However, if Pr.77 (Parameter write selection) is set to "2", you can use both the FR-PA07 an... More Details >>
- No:21698
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , FREQROL-E700 , FREQROL-D700 , FREQROL-F700PJ
-
Advanced magnetic flux vector control
When using the geared motor GM-S(B), set Pr.71 to "13" and also set Pr.9, Pr.80, and Pr.81.Perform auto tuning as required. Perform auto tuning as required. ... More Details >>
- No:21756
- Release Date:2018/08/22 16:29
- Category: Inverters-FREQROL , FREQROL-E700 , FREQROL-A700
-
After setting Pr.340 to "10", you need to power OFF then ON the inverter to make the new setting enabled because you are setting the operation upon power-on.... More Details >>
- No:21759
- Release Date:2018/08/22 16:29
- Category: Inverters-FREQROL , FREQROL-E700 , FREQROL-A700 , FREQROL-F700 , FREQROL-F700P
-
Fault contact state when input side power supply is cut off
The NC contact does not open when the power supply is cut off whether the inverter is operating or ceased.When the input side power supply is cut off, the DC... More Details >>
- No:21958
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-S500
-
Changing main speed at analog signal input
To change the running frequency while the frequency command is input to the terminal 2, adjust the parameters in the following steps:1. Change Pr.77 to "2".2... More Details >>
- No:22025
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-A500
-
No, it cannot. Purchase IQ-Works2 or FR Configurator2. Upgrading to from IQ-Works to IQ-Works2 is for a fee. More Details >>
- No:20829
- Release Date:2018/08/22 16:24
- Category: Engineering Software
-
Yes, the current response is also improved at the same rate. More Details >>
- No:21079
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , FREQROL-A800
-
Yes, it does. (There are some restrictions. More Details >>
- No:21082
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , Options , FREQROL-A800