FAQ within [ Drive Products ]
-
Items controllable via CC-Link
1. Not all items can be controlled. - Functions that cannot be controlled JOG, AU, CS, OH, X10, X11, X12, and X16 functions (Other functions can be control... More Details >>
- No:21459
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-A500 , FREQROL-E500
-
The inverter alarm "OV3" occurs when the main circuit DC voltage inside the inverter goes higher than the preset value due to the regenerative power returned... More Details >>
- No:21438
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-A024
-
It is considered that communication settings between the inverter and personal computer do not match. Check if settings such as communication rate and stop b... More Details >>
- No:21431
- Release Date:2018/08/22 16:27
- Category: Engineering Software
-
Frequent occurrences of OL means that the inverter is overloaded. Since the inverter can go faulty if it is constantly overloaded, you need to take a counter... More Details >>
- No:21430
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-E500
-
The reactor built in the FREQROL-A201 series is intended to stabilize operation of the converter circuit and differs from the FR-BAL. Note that when performi... More Details >>
- No:21421
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , Options , Others
-
Ensure that the inverter is in the PU operation mode and stopped, change the following parameters: 1. Read Pr.923 (Built-in frequency setting potentiometer g... More Details >>
- No:21416
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-E500
-
The current value can be displayed on the operation panel without regard to the setting of monitor-related parameters. As the current value remains 0 A, the ... More Details >>
- No:21405
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL
-
Countermeasures when input power supply is turned off upon equipment fault
1. When the inverter power supply is turned OFF, the inverter is disconnected from the CC-Link network. However, since the CC-Link master station has the aut... More Details >>
- No:21390
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-A500 , FREQROL-E500
-
The output current monitor of the inverter displays the output current effective value of the three phases measured by the current sensor. It does not displa... More Details >>
- No:21373
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-E500
-
Vector control of the inverter
The speed fluctuation ratio under Advanced magnetic flux vector control of the FR-A500 is as follows. Without encoder: ±1% With encoder (with A5AP): ±0. 02 %... More Details >>
- No:21369
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-A500