FAQ


FAQAbout Products
FAQ
Keyword Search
Drive Products
-
FREQROL-A800(142)
FREQROL-F800(89)
FREQROL-A700(351)
FREQROL-D700(260)
FREQROL-E700(393)
FREQROL-F700(295)
FREQROL-F700P(294)
FREQROL-F700PJ(251)
FREQROL-A024(40)
FREQROL-A100(21)
FREQROL-A200(32)
FREQROL-A500(119)
FREQROL-B(9)
FREQROL-E500(84)
FREQROL-F400(2)
FREQROL-F500(15)
FREQROL-S500(11)
FREQROL-U100(16)
FREQROL-V200(51)
FREQROL-Z020(1)
FREQROL-Z024(2)
FREQROL-Z100(2)
FREQROL-Z123(2)
FREQROL-Z200(3)
FREQROL-Z300(2)
SC-A(12)
Engineering Software(41)
Magnet motor drive(9)
Peripheral devices(7)
Options(127)
Plug-in Options(30)
Others(53)
FAQ within [ Drive Products ]
-
FR-A800 "Parameter for the communication setting"
These parameters are used for the communication compatible with the communication protocol of the Ethernet IP of the HMS optional circuit board (A8NEIP_2P). More Details >>
- No:20824
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , FREQROL-A800
-
Yes. It can be carried out like under the dancer feedback speed control. More Details >>
- No:20885
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , FREQROL-A800
-
DC application method (Pr.162 = 0 or 10): 4 Hz or lower is regarded as 0 Hz. AC application method (Pr.162 = 3 or 13): It is not defined since it depends on ... More Details >>
- No:20905
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , FREQROL-A800 , FREQROL-F800
-
Set 3 kg (intermediate value) for the load weight 1 to 5 kg. More Details >>
- No:20953
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , FREQROL-A800
-
Not available. When using the motor thermistor function, use the dedicated motor V5RU with a thermistor. More Details >>
- No:21003
- Release Date:2018/08/22 16:25
- Category: FREQROL-A800 , Plug-in Options
-
The number of timer points is 16 for the high speed and low speed in total. More Details >>
- No:21056
- Release Date:2018/08/22 16:25
- Category: FREQROL-A800 , FREQROL-F800
-
For the FR-F800 series, in addition to the conventional Optimum excitation control, Advanced optimum excitation control with the improved starting torque is ... More Details >>
- No:21072
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , FREQROL-F800
-
"OV3" occurs during an inverter stop.
An error may have occurred due to the rise of the main circuit voltage of the inverter caused by a power surge. Check for the power supply voltage. If the ca... More Details >>
- No:21383
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-A024
-
Motor characteristics at low input voltage
Since the dedicated motor is designed with the rated voltage of approximately 320 V, it can produce sufficient torque for the input voltage of 380 V. Therefo... More Details >>
- No:21434
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-V200
-
Automatic restart after instantaneous power failure
The inverter has the automatic restart after instantaneous power failure function. By setting Pr.61 to other than "9999", the encoder detects the speed of th... More Details >>
- No:21642
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , FREQROL-V200
741-750 of Total 1353