FAQ within [ Drive Products ]
-
For output signals, up to 10 points (RXn2 to RXB) can be assigned. It is possible if the number of the importing signal points are within this range. More Details >>
- No:20943
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , Plug-in Options
-
Yes. More Details >>
- No:20910
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , Engineering Software
-
If Pr.361 = 0, the second terminal can be used as the line speed command when X114 is ON, and as the frequency setting value when X114 is OFF. If Pr.361 = 3,... More Details >>
- No:20891
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , FREQROL-A800
-
Yes, because the same enclosure cut dimensions is adopted. More Details >>
- No:20866
- Release Date:2018/08/22 16:24
- Category: Options
-
It is for the HIV cable. More Details >>
- No:20850
- Release Date:2018/08/22 16:24
- Category: Options
-
The X114 signal is for switching the control to the dancer control or tension sensorless torque control. The signal input becomes invalid during operation be... More Details >>
- No:20845
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , FREQROL-A800
-
The file created with the Japanese version can be read in the English version. The file created with the English version can also be read in the Japanese ver... More Details >>
- No:20832
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , Engineering Software
-
The response delay time is 10 ms normally and 100 ms at startup. More Details >>
- No:20821
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , Plug-in Options
-
Combination of the FR-F800 and MM-EFS
Yes, it can. Set "12" or "112" to the MM-EFS capacity used for Pr.80 (Motor capacity) and Pr.998 (PM parameter initialization). More Details >>
- No:20820
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , FREQROL-F800
-
Yes. More Details >>
- No:20810
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , Others