FAQ within [ Drive Products ]
-
They cannot be set with the frequency. Because the command is input at the line speed, consider the line speed of the initial winding diameter at 20 Hz. The ... More Details >>
- No:20888
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , FREQROL-A800
-
It is 2 to 3 ms. By setting Pr.289 Inverter output terminal filter and Pr.699 Input terminal filter, the FR-A700 can be compatible with the response of the t... More Details >>
- No:20899
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , FREQROL-A800 , FREQROL-F800
-
Until now the DC has been applied to perform the frequency search. When Pr.162 = 3 or 13, the impact is reduced by detecting the phase and performing the sea... More Details >>
- No:20904
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , FREQROL-A800 , FREQROL-F800
-
Yes, the current is limited under the PM sensorless control. More Details >>
- No:20936
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , FREQROL-F800
-
Do not carry out a pressure test. As for a megger test, carry out the test with 500 VDC as describes in the Instruction Manual of the inverter. More Details >>
- No:20967
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , Others , Peripheral devices
-
Communication specifications for connection of multiple inverters
Use the RS485 terminal for the multiple communication of the A series/F series inverters.* Communication with the PU connector is only one-to-one connection. More Details >>
- No:20998
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , FREQROL-A800 , FREQROL-F800
-
Gain adjustment under the speed control
Since the lower limit has been internally set, 3% or less is recognized as 3%. More Details >>
- No:21016
- Release Date:2018/08/22 16:25
- Category: FREQROL-A800 , FREQROL-F800
-
It is 1 s interval. More Details >>
- No:21055
- Release Date:2018/08/22 16:25
- Category: FREQROL-A800 , FREQROL-F800
-
Yes. More Details >>
- No:21062
- Release Date:2018/08/22 16:25
- Category: FREQROL-A800 , Options
-
Yes. More Details >>
- No:21063
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , Options , Others , FREQROL-B