FAQ within [ Drive Products ]
-
Both settings of Pr.83 and Pr.84 are enabled immediately. However, the output voltage is not changed because the value of Pr.83 has little influence on Vecto... More Details >>
- No:21022
- Release Date:2018/08/22 16:25
- Category: FREQROL-A800
-
The value is displayed in 0.1 rpm increments under Vector control. However, the value is rounded down to the first decimal place and displayed in 1 rpm incre... More Details >>
- No:21021
- Release Date:2018/08/22 16:25
- Category: FREQROL-A800
-
Yes, the resistance values are the same. More Details >>
- No:21020
- Release Date:2018/08/22 16:25
- Category: FREQROL-A800
-
The AC reactor (FR-HAL) is built in the FR-A701. (The circuit type in the Harmonic Suppression Guidelines is three-phase bridge (capacitor smoothed), with re... More Details >>
- No:21011
- Release Date:2018/08/22 16:25
- Category: FREQROL-A700
-
Yes. More Details >>
- No:21009
- Release Date:2018/08/22 16:25
- Category: FREQROL-A800
-
Only the parameter setting values (USB memory parameter copy file: CP1 file) read from the inverter to USB memory can be edited. Customers cannot generate a ... More Details >>
- No:21007
- Release Date:2018/08/22 16:25
- Category: Engineering Software
-
The ON level is the power supply voltage -3 V or higher and the OFF level is 3 V or lower. More Details >>
- No:21002
- Release Date:2018/08/22 16:25
- Category: FREQROL-A800 , Plug-in Options
-
Combination of the FR-A800 and MM-BF
Select the models so that "MM - BF rated current value × 1.05 < FR-A820 rated output current value". More Details >>
- No:21000
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , FREQROL-A800
-
No, you cannot have both. The Japanese version of Configurator2 must be uninstalled before installing the English version. More Details >>
- No:20992
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , Engineering Software
-
For 200 V: The cover is attached for 15 K or lower. No cover is attached for 18.5 K or higher. For 400 V: The cover is attached for 55 K or lower. No cover i... More Details >>
- No:20988
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , Options