Using FR-A540 inverter on CC-Link
Answer to question 1 When the CC-Link option goes faulty, OPT (option error) occurs and the inverter's fault output is triggered. When communication is lost ... More Details >>
- No:21391
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-A500
-
"OV3" occurs during an inverter stop.
An error may have occurred due to the rise of the main circuit voltage of the inverter caused by a power surge. Check for the power supply voltage. If the ca... More Details >>
- No:21383
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-A024
-
Check the setting value of Pr.37 (Speed display). When the machine speed is set, Pr.811 is disabled. Change the setting to the rotation speed. More Details >>
- No:21161
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , FREQROL-A700
-
"E.OSD" occurs when the rotation speed is not decreased for one second despite the start command (STF, STR) is turned OFF. More Details >>
- No:21159
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , FREQROL-A700
-
- No:23649
- Release Date:2018/09/14 15:10
- Category: MELSERVO-J4
-
Is the forced stop signal wiring necessary?
For the safety of use, the wiring is recommended. If not using the wiring, set the parameter No. PA04 to “0100”. More Details >>
- No:23645
- Release Date:2018/09/14 15:10
- Category: MELSERVO-J4
-
You can use the Hioki Memory HiCorder and clamp-on AC/DC high tester.You can observe the inverter's frequency in one of the following two methods:1. Attach t... More Details >>
- No:22082
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-A500 , FREQROL-E500
-
A motor overheats (the current increases) when the load is heavy.When the electronic thermal O/L relay works, you need to mitigate the load.If the current is... More Details >>
- No:22042
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
Before you change Pr.7 and Pr.8, you must switch to the PU operation mode. Switch to the PU operation mode and change them. More Details >>
- No:21984
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-F500
-
We provide FR-E720-□KNC that is the CC-Link built-in model. More Details >>