FAQ within [ Drive Products ]
-
Watt-hour meter clear and operation hour meter clear
The values are set to Pr.170 and 171 when the monitor value of cumulative power and actual operation time overflows. It does not affect the operation. Use it... More Details >>
- No:21197
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
You can use an inverter for fan and pump with the compressor, but it is not recommended for an application that the motor load rapidly increases. More Details >>
- No:21443
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-A100
-
Can a single potentiometer operate two speed controller?
A single potentiometer cannot operate two speed controller. Reason: Since the control circuit and main circuit of the SC-A speed controller are not insulated... More Details >>
- No:21578
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , SC-A
-
Check the parameters listed below necessary for tuning again.Pr.9, Pr.71, Pr.80, Pr.81, Pr.83, Pr.84, and Pr.96 More Details >>
- No:21726
- Release Date:2018/08/22 16:29
- Category: Inverters-FREQROL , FREQROL-E700 , FREQROL-A700
-
Encoder cable length restriction
If the cable length is longer than 100 m, speed may not be read correctly due to voltage drop and waveform deformation of the encoder signal. Therefore, use ... More Details >>
- No:21932
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-V200
-
The number of terminals: There are the same input terminals as F700P and the following terminals (4 points) are added. Safety: SI1, SI2, SIC 24 V power suppl... More Details >>
- No:21070
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , FREQROL-F800
-
Check that the correct rated motor current is set in Pr.9 (Electronic thermal O/L relay). No parameter is available for setting the operation time of the ele... More Details >>
- No:21291
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , FREQROL-E700 , FREQROL-D700 , FREQROL-A700 , FREQROL-F700PJ
-
Wire length between inverter and motor
1. Wiring length between the inverter and the motor should be 500 m or less. For 0.75 kW or lower motors, the following relationship is true: Capacity... More Details >>
- No:21392
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL
-
It is considered that communication settings between the inverter and personal computer do not match. Check if settings such as communication rate and stop b... More Details >>
- No:21431
- Release Date:2018/08/22 16:27
- Category: Engineering Software
-
Which is the recommended digital counter?
We recommend the following digital counter: (Connect it between the terminals FM and SD.) Manufacturer: KOYO ELECTRONICS INDUSTRIES CO., LTD.Model: TC-41 More Details >>
- No:21469
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , Others , FREQROL-A500