FAQ within [ Drive Products ]
-
When controlling motor with brake by inverter
Use the RUN signal to turn ON and OFF the brake.Using the MRS (output shutoff) signal to turn ON the brake shuts off the inverter's output and reduces influe... More Details >>
- No:21960
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
Fault contact when connecting separate power supply for each control circuit
Since the inverter's fault contact is an NC contact, it does not open unless a fault occurs.Therefore, when the control power supply (and main circuit power ... More Details >>
- No:22035
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
Safety stop function of the FR-E700/FR-D700
Up to two. More Details >>
- No:20827
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL
-
Vector control cannot be selected unless Pr.862 is set to 1. Only the first motor is supported in the motor setting of FR Configurator2. More Details >>
- No:20847
- Release Date:2018/08/22 16:24
- Category: Engineering Software
-
The torque limit setting is defined as an absolute value. Thus, when -100% is written to the torque limit, the torque is limited at 100%. More Details >>
- No:20920
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL
-
Yes, it is preferred. The accuracy becomes worse when the gap between the setting value and actual value increases. More Details >>
- No:20932
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL
-
Yes, it is included. More Details >>
- No:20933
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL
-
Difference in the monitor function
The same value is displayed in the initial setting. When negative output is enabled by setting "0" to Pr.290 (Monitor negative output selection), there are f... More Details >>
- No:20938
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL
-
Because the internal reset processing is performed when the power supply is turned OFF, the fault state cannot be held. The details of the faults are saved i... More Details >>
- No:20942
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , Options
-
The FR-CC2 has a built-in EMC filter (radio noise filter). More Details >>
- No:20951
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL
71-80 of Total 1354