FAQ
FAQAbout Products
FAQ
Keyword Search
Drive Products
-
FREQROL-A800(144)
FREQROL-F800(89)
FREQROL-A700(352)
FREQROL-D700(261)
FREQROL-E700(394)
FREQROL-F700(296)
FREQROL-F700P(295)
FREQROL-F700PJ(252)
FREQROL-A024(40)
FREQROL-A100(21)
FREQROL-A200(32)
FREQROL-A500(123)
FREQROL-B(10)
FREQROL-E500(85)
FREQROL-F400(2)
FREQROL-F500(15)
FREQROL-S500(11)
FREQROL-U100(16)
FREQROL-V200(52)
FREQROL-Z020(1)
FREQROL-Z024(2)
FREQROL-Z100(2)
FREQROL-Z123(2)
FREQROL-Z200(3)
FREQROL-Z300(2)
SC-A(12)
Engineering Software(43)
Magnet motor drive(9)
Peripheral devices(7)
Options(129)
Plug-in Options(30)
Others(53)
FAQ within [ Drive Products ]
-
System environment variable of the Modbus-RTU communication
Other than "0" can be input. The inverter is reset by writing any numerical value. More Details >>
- No:21224
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
No, they are not connected inside the inverter. More Details >>
- No:21225
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
Noise effect of CC-Link IE communication
The same test as CC-Link is performed, and we confirmed no problem. More Details >>
- No:21226
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
Inverter installation when using the FR-A7NCE
Normally, the required space for A700 3.7K or lower is 1 cm. However, when using CC-Link IE, it needs to be separated for 5 cm or more to pass the cable. More Details >>
- No:21227
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
Writing set frequency by CC-Link communication
No error will occur because up to 400 Hz that is the upper limit of the setting range can be written. More Details >>
- No:21229
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
Remote register when instruction code execution request is issued at CC-Link communication
The value "0" is stored. More Details >>
- No:21234
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
Pr.268 (Monitor decimal digits selection) during CC-Link communication
No, it is not changed. Pr.268 is the parameter for the operation panel. More Details >>
- No:21241
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
Dancer control during CC-Link communication
It is not possible under the dancer control. When the negative data is written, it is handled as the positive data in operation. Example) When Pr.541 is set ... More Details >>
- No:21243
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
Comparison of the speed change rate
Speed fluctuation ratio differs depending on the control method as follows. - V/F control?????????2 to 5% (At the encoder feedback: 0.02%)- General-purpose m... More Details >>
- No:21377
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL
-
Common connection of the terminal SD
There is no problem for only the terminal SD connection because undesirable current will not be flown. More Details >>
- No:21379
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL
71-80 of Total 1368